Showven uFlamer Volcano User Manual Download Page 11

 

 

10

 

flame 

Single ignition SHORT 

flame 

Static 

0.1s 

11-12 

Single ignition SHORT 

flame 

Static 

0.1s 

13-15 

Single ignition LONG 

flame 

Static 

0.28s 

16-17 

Single ignition LONG 

flame 

Static 

0.28s 

18-20 

Single ignition LONG 

flame 

Static 

0.28s 

21-22 

Single ignition LONG 

flame 

Static 

0.28s 

23-25 

10 

Single ignition LONG 

flame 

Static 

0.28s 

26-28 

 

Step Sequences List 

Sequence 

No. 

Ignition 

head No. 

Description 

Flame 

Activity 

Firing Duration 

(for reference) 

CH5 DMX 

Reference 

Value 

11 

Step 1-5 

SHORT flame Step 

sequence 

L -> R 

0.54s 

29-30 

12 

Step 5-1 

SHORT flame Step 

sequence 

R -> L 

0.54s 

31-33 

13 

Step 

1>3>5>2>4 

SHORT flame Step 

sequence 

L>M>R>L>

0.54s 

34-35 

14 

Step 

5>3>1>4>2 

SHORT flame Step 

sequence 

R>M>L>R>

0.54s 

36-38 

15 

Step 

1>5>2>3>4 

SHORT flame Step 

sequence 

L>R>L>M>

0.54s 

39-40 

16 

Step 

5>1>4>3>2 

SHORT flame Step 

sequence 

R>L>R>M>

0.54s 

41-43 

17 

Step1>5>2

>4>3 

SHORT flame Step 

sequence 

L>R>L>R>

0.54s 

44-45 

18 

Step 

5>1>4>2>3 

SHORT flame Step 

sequence 

R>L>R>L>

0.54s 

46-48 

19 

Step 

2>4>1>5>3 

SHORT flame Step 

sequence 

L>R>L>R>

0.54s 

49-50 

20 

Step 

4>2>5>1>3 

SHORT flame Step 

sequence 

R>L>R>L>

0.54s 

51-53 

21 

Step 

2>4>3>1>5 

SHORT flame Step 

sequence 

L>R>M>L>

0.54s 

54-56 

22 

Step 

4>2>3>5>1 

SHORT flame Step 

sequence 

R>L>M>R>

0.54s 

57-58 

23 

Step 

2>3>4>1>5 

SHORT flame Step 

sequence 

L>M>R>L>

0.54s 

59-61 

24 

Step 

4>3>2>5>1 

SHORT flame Step 

sequence 

R>M>L>R>

0.54s 

62-63 

25 

Step 

3>1>5>2>4 

SHORT flame Step 

sequence 

M>L>R>L>

0.54s 

64-66 

26 

Step 

3>5>1>4>2 

SHORT flame Step 

sequence 

M>R>L>R>

0.54s 

67-68 

27 

Step 

3>2>4>1>5 

SHORT flame Step 

sequence 

M>L>R>L>

0.54s 

69-71 

28 

Step 

3>4>2>5>1 

SHORT flame Step 

sequence 

M>R>L>R>

0.54s 

72-73 

Summary of Contents for uFlamer Volcano

Page 1: ...1 USER MANUAL uFlamer Volcano V1 1 Showven Technologies Co Ltd ...

Page 2: ... out of service immediately Be sure the device is in good operating condition before use If fail to fire correctly immediately shut down and check it accordingly Any questions please always contact SHOWVEN info showven cn for help Be sure to use high quality flame fluid otherwise it is easily lead to failure or danger Be careful when refill the flame fluid tank Please keep flame fluid away from he...

Page 3: ...mp plug and play system Flames up to 10m Reinforced stainless steel housing 25L built in stainless steel fuel tank Support automatic refueling station Real time fuel level display both electronically and mechanically Safety switch key Integrated valve block design Premium and independent jet valve Customized water proof ignitor IPX3 rain proof can be used in rainy day DMX control with both 3 pin a...

Page 4: ...3 Structure of uFlamer Volcano 1 Fuel Tank Lid 2 Top Panel 3 Handle 4 Control Panel 5 Safety Loop Connection dimension diagram of bottom bracket ...

Page 5: ...el 2 Pressure indicator 3 Safety indicator 4 5 pin XLR Socket 5 110V 220V Power Socket 6 Auto reset Fuse 7 Fuel Input Quick Coupler G1 4 ISO7241B 8 Safety Lock 9 ON OFF Switch 10 3 pin XLR Socket 11 DC 9V 60V fireworks igniter signal port Operation Panel ...

Page 6: ...ine DMX DMX address 1 value from 1 512 M Channel Mode 6CH P 6CH P professional channel mode 6CH N normal channel mode 6CH S safety channel mode Second Line P Pressure Value 100 100 10bar L Liquid level 50 5 Alert Message Alert Message Explanation E0 Test Mode Safety lock located at TEST MODE Factory Mode DMX signal blocked in factory mode Invert ON When turned on all angles will be mirrored Prim V...

Page 7: ...fore test 2 Igniter Ignition from head No 1 to 5 3 Relief Valve Relief valve will be on and off 3 times 4 Priming Valve Priming Valve will on and off 3 times 5 Jet Valve 1 6s after Relief Valve was on related Jet Valve will on and off 3 times Keep safety Lock located at USER MODE before test 6 Jet Valve 2 7 Jet Valve 3 8 Jet Valve 4 9 Jet Valve 5 Ext Ignite OFF ON Trigger through 9 60V ExtIgnite s...

Page 8: ...ide are indicated in the picture 3 Safety distances for uFlamer Volcano are indicated in above picture At least 15m in all projection directions at least 10m to the audience side and control side 2 Quick Operation Sheet Immediately upon receiving the machine carefully unpack the packing carton check the machine received in good condition Ensure safety operation of machine please do following below...

Page 9: ...l activated but there is no flame Pressure Relief Host controller Press pre heat key light off DMX console switch DMX value of channel 6 to 0 49 201 255 Press the safety lock to USER MODE Before switch to USER MODE Please strictly follow the safety distance requirements remove all human animal or flammable objects in the danger area Pressurise Host controller Press pre heat button light on DMX con...

Page 10: ...finitions Below schematic shows 5 heads and the projection directions of uFlamer Volcano from Audience Side view 4 Firing sequence list uFlamer Volcano with more than 97 preset firing sequences Operator use related channel DMX value or sequence No to access certain sequence Sequence list as below Single Ignition Sequence List Sequence No Ignition head No Description Flame Activity Firing Duration ...

Page 11: ...6 38 15 Step 1 5 2 3 4 SHORT flame Step sequence L R L M R 0 54s 39 40 16 Step 5 1 4 3 2 SHORT flame Step sequence R L R M L 0 54s 41 43 17 Step1 5 2 4 3 SHORT flame Step sequence L R L R M 0 54s 44 45 18 Step 5 1 4 2 3 SHORT flame Step sequence R L R L M 0 54s 46 48 19 Step 2 4 1 5 3 SHORT flame Step sequence L R L R M 0 54s 49 50 20 Step 4 2 5 1 3 SHORT flame Step sequence R L R L M 0 54s 51 53 ...

Page 12: ... L R M L 1 45s 108 109 43 Step1 5 2 4 3 LONG flame Step sequence L R L R M 1 45s 110 112 44 Step 5 1 4 2 3 LONG flame Step sequence R L R L M 1 45s 113 114 45 Step 2 4 1 5 3 LONG flame Step sequence L R L R M 1 45s 115 117 46 Step 4 2 5 1 3 LONG flame Step sequence R L R L M 1 45s 118 119 47 Step 2 4 3 1 5 LONG flame Step sequence L R M L R 1 45s 120 122 48 Step 4 2 3 5 1 LONG flame Step sequence ...

Page 13: ... LMR LR 0 25s 179 181 71 Step 15 234 SHORT flame Step sequence LR LMR 0 25s 182 183 72 Step 234 15 SHORT flame Step sequence LMR LR 0 25s 184 186 73 Step 15 3 24 LONG flame Step sequence LR M LR 0 86s 187 188 74 Step 24 3 15 LONG flame Step sequence LR M LR 0 86s 189 191 75 Step 15 24 3 LONG flame Step sequence LR LR M 0 86s 192 193 76 Step 3 24 15 LONG flame Step sequence M LR LR 0 86s 194 196 77...

Page 14: ... 244 96 234 simultaneously Static User defined 245 247 97 12345 simultaneously Static User defined 248 255 5 DMX control 1 Normal Channel Mode Channel Function CH1 Manual mode head selection 0 all five heads 1 51 head NO 1 52 102 head NO 2 103 153 head NO 3 154 204 head NO 4 205 255 head NO 5 CH2 CH3 Ignition ON OFF 0 253 ignition OFF 254 255 ignition ON CH4 Firing duration setup 0 and 255 is perm...

Page 15: ...253 ignition OFF 254 255 ignition ON CH4 Firing duration setup 0 and 255 is permanent firing 8s is limit duration firing time 5 heads simultaneously firing limit time is 2s 1 254 correspond to 10 2540ms duration time Manual firing duration DMX Value 10ms CH5 Program sequence setup 0 2 no preset sequence set according to CH1 and CH4 3 255 preset sequence DMX Value 2 Sequence No 2 55 round off CH1 a...

Page 16: ... After change the nozzle please adjust the ignitor s position according to below parameters The default position when we ship out from factory is for Nozzle M standard nozzle When replace to nozzle L indoor nozzle need to remove the ignitor a little bit to the center makes the ignitor closer to the fuel stream Nozzle a mm b mm Short flame height m Long flame height m M 4 0 5 4 0 5 5 7 8 10 L 2 5 0...

Page 17: ... of uFlamer Volcano 3 5 standard dynamic modes Synchronization Center to Ends Ends to Center Left to Right Right to Left And an user definable Special Effect mode support 8 files each file support 36000 lines maximum effects lasts for 30min 4 Multi trigger sources manual music or midi input 5 RDMX monitoring function system can send back uFlamer Volcano working status info such as pressure warming...

Page 18: ...pment if the flame shape is seriously deformed or the fuel injection line is significantly deformed or coarsened the nozzle should be removed immediately for cleaning 3 Maintenance of the O ring If it is found that the O ring of the nozzle is damaged or ageing when cleaning the nozzle the O ring should be replaced in time material and size of O ring fluororubber O ring the outermost diameter is 14...

Page 19: ...out factory permission Below situations NOT included in warranty service 1 Damage caused by improper transportation usage management and maintenance or damage caused by human factors 2 Disassemble modify or repair products without Showven s permission 3 Damage caused by external reasons lightning strike power supply etc 4 Damage caused by improper installation or use For product damage not include...

Page 20: ......

Page 21: ......

Page 22: ...Tel 86 731 83833068 Web www showven cn E mail info showven cn Add Liuyang Economic Development Zone Changsha 410300 Hunan Province P R China ...

Reviews: