13
84
1245
Multi ignition SHORT
flame
Static
0.1s
215-216
85
234
Multi ignition SHORT
flame
Static
0.1s
217-219
86
135
Multi ignition SHORT
flame
Static
0.1s
220-221
87
15
Multi ignition SHORT
flame
Static
0.1s
222-224
88
24
Multi ignition SHORT
flame
Static
0.1s
225-226
89
12345
Multi ignition LONG
flame
Static
0.28s
227-229
90
1245
Multi ignition LONG
flame
Static
0.28s
230-232
91
234
Multi ignition LONG
flame
Static
0.28s
233-234
92
135
Multi ignition LONG
flame
Static
0.28s
235-237
93
15
Multi ignition LONG
flame
Static
0.28s
238-239
94
24
Multi ignition LONG
flame
Static
0.28s
240-242
95
3
Multi ignition LONG
flame
Static
User defined
243-244
96
234
simultaneously
Static
User defined
245-247
>97
12345
simultaneously
Static
User defined
248-255
5. DMX control
1. Normal Channel Mode
Channel
Function
CH1
Manual mode head selection
0: all five heads 1-51: head NO.1
52-102: head NO.2 103-153: head NO.3
154-204: head NO. 4 205-255: head NO.5
CH2
/
CH3
Ignition ON/OFF
0~253: ignition OFF;
254~255: ignition ON
CH4
Firing duration setup
0 and 255 is permanent firing (8s is limit duration firing time, 5 heads
simultaneously firing limit time is 2s);
1~254 correspond to 10~2540ms duration time (Manual firing duration = DMX
Value * 10ms)
CH5
Program sequence setup
0-2: no preset sequence; set according to CH1 and CH4;
3~255: preset sequence. DMX Value = 2+ Sequence No. * 2.55 (round off). CH1 and
CH4 invalid.
CH6
Mode setup
0~49: Pressure Relief Mode (Emergency Stop)
50~200: Firing Mode
201~255: Pressure Relief Mode (Emergency Stop)
Summary of Contents for uFlamer Volcano
Page 1: ...1 USER MANUAL uFlamer Volcano V1 1 Showven Technologies Co Ltd ...
Page 20: ......
Page 21: ......