24
DMX Control ARC1+S
Channel
Value
Function
1
000 – 255
Dimmer
0 – 100 %
2
000 – 255
Red
0 – 100 %
3
000 – 255
Green
0 – 100 %
4
000 – 255
Blue
0 – 100 %
5
000 – 255
Strobe
0 – 100 %
DMX Control HSV
Channel
Value
Function
1
000 – 255
Hue (Color variations)
0 – 100 %
2
000 – 255
Saturation of color Red
0 – 100 %
3
000 – 255
Value (Dimmer)
0 – 100 %
DMX Control BLOCK
Channel
Value
Function
1
000 – 255
Module 1 red
0 – 100 %
2
000 – 255
Module 1 green
0 – 100 %
3
000 – 255
Module 1 blue
0 – 100 %
4
000 – 255
Module 2 red
0 – 100 %
5
000 – 255
Module 2 green
0 – 100 %
6
000 – 255
Module 2 blue
0 – 100 %
Maintenance
The Eventspot 1900 mkII requires almost no maintenance.
However, you should keep the unit clean.
Otherwise, the fixture’s light-output will be significantly reduced. Switch of the
power on/off (6)
switch
at the rear
and then wipe the cover with a damp cloth.
Wipe the front glass panel clean with glass
cleaner and a soft cloth. Do not use alcohol or solvents. The front glass panel will require weekly
cleaning, as smoke-fluid tends to build up residues, reducing the light-output very quickly.
Do not
immerse in liquid.
Keep connections clean. Disconnect electric power, and then wipe the DMX connections with a
damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric
power.
Troubleshooting
No Light
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit
operates properly, do not carry out following steps.
If the light effect does not operate properly, refer servicing to a technician.
Response: Suspect two potential problem areas: the battery and the LED.
1.
Battery. Check that the battery is fully charged. The red LED in the
power on/off (1)
button should
light continuously if the Eventspot is active.