10
Charging the built in battery
1.
In order to charge the battery, you need either the optional
42719, Charger for Eventspot 1900 mkII
or the optional 42718 flightcase with built in chargers.
2.
Turn off the
power on/off (6)
switch.
3.
Place the Eventspot on the charger.
4.
While the battery is charging, the red LED in the
power on/off (1)
button will light.
5.
When the battery is fully charged, the red LED in the
power on/off (1)
button will dim.
Important!
•
Do not charge for more than 24 hours.
•
Recharge within 3 days of use.
•
When charging your Eventspot in the flightcase, make sure that the flightcase is open.
•
Store with full load.
•
Turn of the
power on/off (6)
switch at the rear when storing for more than 7 days.
•
Store in an upright position.
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or
to run synchronized shows on two or more fixtures set to a master/slave operating mode. The
combined number of channels required by all the fixtures on a serial data link determines the number
of fixtures the data link can support.
The Eventspot 1900 mkII uses up to 15 channels.
Important:
Fixtures on a serial data link must be daisy chained in one single line. To comply with the
EIA-485 standard no more than 30 devices should be connected on one data link.
Connecting more than 30 fixtures on one serial data link without the use of a DMX
optically isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended DMX data link distance: 100 meters
Maximum recommended number of LED Pars on a DMX data link: 30 fixtures
@ 220V: 12 units may be connected in series
@120V: 6 units may be connected in series
Data Cabling
To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX
cables directly from a dealer/distributor or construct your own cable. If you choose to create your
own cable please use data-grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
DAP Audio Certified DMX Data Cables
• DAP Audio Basic microphone cable for allround use.
bal. XLR/M 3 p. > XLR/F 3 p.
Ordercode:
FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.).
• DAP Audio cable f
or the demanding user with exceptional audio-qualities and connector made
by Neutrik®.
Ordercode:
FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.).