background image

 

Ordercode: 40296 

Data Flash Strobe  

Before the initial start-up, please make sure that there is no damage caused by transportation.  

Should there be any, consult your dealer and do not use the device. 

 

To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 

follow the safety instructions and warning notes contained in this manual. 

 

Please consider that damages caused by manual modifications to the device are not subject to 

warranty. 

 

This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 

 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 

this manual or any unauthorized modification to the device. 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 

connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the fixture holding it by the projector-head, as the mechanics may be damaged. Always 

hold the fixture by the transport handles. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 

Allow the fixture to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly 

fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 

the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 

cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 

engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 

switch it on immediately. The arising condensation water might damage your device. Leave the 

device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 

(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The fixture must be installed beyond the reach of children. Never leave the unit 

running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Data Flash Strobe. The 

manufacturer will not accept liability for damages caused by the misuse or incorrect installation of 

this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 

conductor to earth. 

 

  

 

 

   

 

Summary of Contents for Data Flash Strobe

Page 1: ...Data Flash Strobe V3 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40296 MANUAL ENGLISH...

Page 2: ...trobe Sound controlled 9 Multiple Data Flash Strobes Master Slave control 9 Multiple Data Flash Strobes DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressin...

Page 3: ...includes Showtec Data Flash Strobe Pro power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration of...

Page 4: ...is firmly closed and all screws are tightly fastened Only operate the device after having familiarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep th...

Page 5: ...operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concer...

Page 6: ...h the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW CO...

Page 7: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this chec...

Page 8: ...C 50 60Hz Power consumption 120W DMX channels 2 3 12 channels LCD display for easy setup Light source SMD LEDs Control modes Auto Built in Programs Sound controlled Master Slave DMX Control protocol D...

Page 9: ...d Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non...

Page 10: ...r supply socket 03 Turn on the music If the device is set to sound control then the Data Flash Strobe will react to the beat of the music Please see page 15 for more information about the sound contro...

Page 11: ...onnect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric ma...

Page 12: ...ly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic...

Page 13: ...erlapping channels in order to control each Data Flash Strobe correctly If two or more Data Flash Strobes are addressed similarly they will work similarly Controlling After having addressed all Data F...

Page 14: ...Ordercode 40296 Data Flash Strobe Menu Overview 13...

Page 15: ...the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to toggle through the 25 built in programs 04 Once you have selected one of the programs press the SETUP butto...

Page 16: ...ble options are 5 Sound control Mode 01 Press the MODE button and then the UP DOWN buttons until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to set the so...

Page 17: ...ress the MODE button and then the UP DOWN buttons until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to choose between the 6 available options and 04 Press...

Page 18: ...on to open the menu and then press the UP DOWN buttons to choose Yes or No 11 Press the SETUP button again to confirm your choice If you have chosen Yes the factory settings will be restored 12 In the...

Page 19: ...l 2 Strobe Dimmer must be open 0 4 Closed 5 127 Linear strobe from low to high frequency 0 20Hz ALL LEDs 128 189 Random strobe from low to high frequency ALL LEDs 190 255 Random strobe RANDOM LED RING...

Page 20: ...m dark to brightest 0 100 Channel 7 Section 6 Dimmer must be open 0 255 Gradual adjustment section 6 from dark to brightest 0 100 Channel 8 Section 7 Dimmer must be open 0 255 Gradual adjustment secti...

Page 21: ...a damp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front lens will require weekly cleaning as smoke fluid tends to build up re...

Page 22: ...missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not ter...

Page 23: ...effects Light source SMD LEDs Dimmer 0 100 Strobe 0 20Hz Housing Aluminum DMX control via standard DMX controller DMX 512 On Board LCD display for easy setup Control Auto Built in Programs Sound cont...

Page 24: ...Ordercode 40296 Data Flash Strobe Dimensions 23...

Page 25: ...Ordercode 40296 Data Flash Strobe Notes 24...

Page 26: ...Ordercode 40296 Data Flash Strobe 25...

Page 27: ...Ordercode 40296 Data Flash Strobe 26...

Page 28: ...2016 Showtec...

Reviews: