background image

 

Ordercode: 40296 

Data Flash Strobe  

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 

device will serve you for a long time without defects. 

 

The minimum distance between light output and the illuminated surface must be bigger than 1 

meter. 

 

The maximum ambient temperature t

a

 = 40°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40° C. 

 

If this device is operated in any other way than the one described in this manual, the product may 

suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

 

You endanger your own safety and the safety of others! 

 

Rigging 

Please follow the European and national guidelines concerning rigging, trussing and all 

other safety issues. 

 

Do not attempt the installation yourself ! 

Always let the installation be carried out by an authorized dealer ! 

 

Procedure: 

 

If the Data Flash Stobe is lowered from the ceiling or high joists, professional trussing systems have to 

be used. 

 

Use a clamp to mount the Data Flash Strobe, with the mounting bracket, to the trussing system. 

 

The Data Flash Strobe must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net or 

safety cable. 

 

When rigging, derigging or servicing the Data Flash Strobe, always make sure, that the area below 

the installation site is secured and that there are not any unauthorized people around. 

 

 

  

 

 

   

 

Summary of Contents for Data Flash Strobe

Page 1: ...Data Flash Strobe V3 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40296 MANUAL ENGLISH...

Page 2: ...trobe Sound controlled 9 Multiple Data Flash Strobes Master Slave control 9 Multiple Data Flash Strobes DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressin...

Page 3: ...includes Showtec Data Flash Strobe Pro power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration of...

Page 4: ...is firmly closed and all screws are tightly fastened Only operate the device after having familiarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep th...

Page 5: ...operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concer...

Page 6: ...h the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW CO...

Page 7: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this chec...

Page 8: ...C 50 60Hz Power consumption 120W DMX channels 2 3 12 channels LCD display for easy setup Light source SMD LEDs Control modes Auto Built in Programs Sound controlled Master Slave DMX Control protocol D...

Page 9: ...d Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non...

Page 10: ...r supply socket 03 Turn on the music If the device is set to sound control then the Data Flash Strobe will react to the beat of the music Please see page 15 for more information about the sound contro...

Page 11: ...onnect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric ma...

Page 12: ...ly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic...

Page 13: ...erlapping channels in order to control each Data Flash Strobe correctly If two or more Data Flash Strobes are addressed similarly they will work similarly Controlling After having addressed all Data F...

Page 14: ...Ordercode 40296 Data Flash Strobe Menu Overview 13...

Page 15: ...the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to toggle through the 25 built in programs 04 Once you have selected one of the programs press the SETUP butto...

Page 16: ...ble options are 5 Sound control Mode 01 Press the MODE button and then the UP DOWN buttons until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to set the so...

Page 17: ...ress the MODE button and then the UP DOWN buttons until the display shows 02 Press the SETUP button to open the menu 03 Press the UP DOWN buttons to choose between the 6 available options and 04 Press...

Page 18: ...on to open the menu and then press the UP DOWN buttons to choose Yes or No 11 Press the SETUP button again to confirm your choice If you have chosen Yes the factory settings will be restored 12 In the...

Page 19: ...l 2 Strobe Dimmer must be open 0 4 Closed 5 127 Linear strobe from low to high frequency 0 20Hz ALL LEDs 128 189 Random strobe from low to high frequency ALL LEDs 190 255 Random strobe RANDOM LED RING...

Page 20: ...m dark to brightest 0 100 Channel 7 Section 6 Dimmer must be open 0 255 Gradual adjustment section 6 from dark to brightest 0 100 Channel 8 Section 7 Dimmer must be open 0 255 Gradual adjustment secti...

Page 21: ...a damp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front lens will require weekly cleaning as smoke fluid tends to build up re...

Page 22: ...missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not ter...

Page 23: ...effects Light source SMD LEDs Dimmer 0 100 Strobe 0 20Hz Housing Aluminum DMX control via standard DMX controller DMX 512 On Board LCD display for easy setup Control Auto Built in Programs Sound cont...

Page 24: ...Ordercode 40296 Data Flash Strobe Dimensions 23...

Page 25: ...Ordercode 40296 Data Flash Strobe Notes 24...

Page 26: ...Ordercode 40296 Data Flash Strobe 25...

Page 27: ...Ordercode 40296 Data Flash Strobe 26...

Page 28: ...2016 Showtec...

Reviews: