16
Spectral M3000 Zoom Q4 MKII IP65
Product code: 43548
Connecting to Power Supply
DANGER
Electric shock caused by short-circuit
The device accepts AC mains power at 100–240 V and 50/60 Hz. Do not supply power at any other
voltage or frequency to the device.
This device falls under IEC protection class I. Make sure that the device is always electrically connected
to the ground (earth).
Before connecting the device to the socket-outlet:
●
Make sure that the power supply matches the input voltage specified on the information label on
the device.
●
Make sure that the socket-outlet has ground (earth) connection.
Connect the device to the socket-outlet with the power plug. Do not connect the device to a dimmer
circuit, as this may damage the device.
This device is IP65 rated.
●
Do not expose the device to conditions that exceed the rated IP class conditions.
●
Keep the connectors sealed with the rubber caps when the connectors are not in use.
●
Do not connect the cables from above the connectors, if the device is installed outdoors. Make a
‘drip loop’ in the cable so that rain water cannot enter the device.
●
Make sure that the cable run is not too heavy. A heavy cable run can cause damage to the
connectors. If the connectors are damaged, their ingress protection (IP) can deteriorate.
Power Linking of Multiple Devices
This device supports power linking. Power can be relayed to another device via the power OUT
connector. Note that the input and the output connectors have different designs: one type cannot be
connected to the other.
Power linking of multiple devices must be carried out only by instructed or skilled persons.
WARNING
Incorrect power linking may lead to overload of the electrical circuit and result in serious
injuries and damage of property.
To prevent overload of the electrical circuit, when power linking multiple devices:
●
Use cables with sufficient current-carrying capacity. The power cable supplied with the device is not
suitable for power linking of multiple devices.
●
Make sure that the total current draw of the device and all connected devices does not exceed the
rated capacity of the power cables and the circuit breaker.
●
Do not link more devices on one power link than the maximum recommended number.
Maximum recommended number of devices:
●
at 100–120 V: 10 devices Spectral M3000 Zoom Q4 MKII IP65
●
at 200–240 V: 20 devices Spectral M3000 Zoom Q4 MKII IP65
Summary of Contents for 43548
Page 13: ...12 Spectral M3000 Zoom Q4 MKII IP65 Product code 43548 Dimensions Fig 06 ...
Page 23: ...22 Spectral M3000 Zoom Q4 MKII IP65 Product code 43548 Menu Overview ...
Page 41: ...40 Spectral M3000 Zoom Q4 MKII IP65 Product code 43548 ...
Page 42: ...41 Spectral M3000 Zoom Q4 MKII IP65 Product code 43548 ...
Page 43: ...42 Spectral M3000 Zoom Q4 MKII IP65 Product code 43548 ...
Page 44: ... 2022 Showtec ...