30
Phantom 250 Spot
Product code: 40081
Replacing a Gobo From the Rotating Gobo Wheel
DANGER
Electric shock caused by dangerous voltage inside
There are areas within the device where dangerous touch voltage may be present.
Disconnect the device from electrical power supply before service and maintenance, and when the
device is not in use.
Allow the device to cool down before opening the cover.
Use for replacement only gobos that match the specifications below. Using custom gobos that do
not match those specifications may result in damage to the device. Any damage to the device as a
result of using a custom gobo is not covered under warranty.
Do not touch the glass gobo with bare fingers to avoid leaving fingerprints. Handle the gobo only by
the gobo carrier, or wear protective gloves. If you touch the glass, clean with a soft lint-free cloth
and rubbing alcohol.
To replace a rotating gobo, follow the steps below:
Disconnect the device from the mains and allow it to cool completely.
Set the device in horizontal position with the lens facing forward.
Loosen the 4 screws on the head cover, as shown in Fig. 13.
Fig. 13
Carefully remove the head cover from the housing to get access to the rotating gobo wheel.
Turn the rotating gobo wheel by hand until you reach the gobo which you want to replace.