![Showa 5683 Operation Manual Download Page 31](http://html1.mh-extra.com/html/showa/5683/5683_operation-manual_1259939031.webp)
3−10
C) Synchronization between cases
When two more cases are used, synchronization between the cases is needed. As shown in
Figure 3-8, it is possible to maintain synchronization by connecting the interface connectors on
the rear face of the case using synchronization cable (56-402). After the cases are connected,
one case should be set to INT using the synchronization selection switch 2 , and the other
cases should be set to EXT. Note that only amplifier units with the same bridge power frequency
can be installed in a case. It is impossible to share a common case or synchronize between cases
that have amplifiers installed with different bridge power frequencies. Take notice that the bridge
power frequency of
Models 5683
is 5 kHz and that of
Model 5684
is 25 kHz.
Do not set two or more units to INT. Otherwise correct measurement cannot be made, or this may
cause a defect in amplifier units.
Master: INT
Other than master: EXT
Fig.3-8 Rear Panel of Case
Fig.3-9 Connection
of multiple cases
CAUTION