LIMITED WARRANTY

SHM International Corp. warrants the components of this appliance to be free from defects in material and 

workmanship for one (1) year from the date of purchase. SHM International Corp. at its option, will repair or 

replace this product or any component of the product found to be defective during the warranty period. Re-

placement will be made with a new manufactured product or component. If the product is no longer available, 

replacement may be made with a similar product of equal value. This warranty does not include transportation 

or shipping costs of any kind. This your exclusive warranty. 
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transfer-

able. Keep the original sales receipt. Proof of purchase is required to obtain warranty parts. 
This warranty does not cover normal wear of parts such as scratches and dents of the components or damage 

resulting from any of the following:
•  negligent use or misuse of the product, including exposing the product to chemicals or cleaning products not 

approved by SHM International Corp.

•  corrosion, rust or discoloring of any kind
•  use or installation contrary to 

 instructions and applicable building codes, including heating the 

product to temperatures above its rated specifications which can cause considerable warping

•  disassembly, including removal of the product from a built-in installation
•  damage resulting from accident, alteration, misuse, abuse, hostile environments, or improper installation
•  repair or alteration
•  acts of God, such as 

 

 hurricanes, and tornadoes

•  gas cylinders, propane tanks or other fuel delivery systems, including connections to a household fuel supply
•  usage other than single-family household use such as commercial or industrial use
•  minor warping or discoloration of parts, which is normal and not a defect under this warranty

DO NOT RETURN THIS PRODUCT TO THE PLACE OF PURCHASE

If the appliance does not operate properly, first thoroughly carry out the instructions provided with the unit to 

ensure that the appliance is installed correctly and check the troubleshooting section in the use and care manual.
We recommend you return the warranty registration card so that you can be contacted when any questions of 

safety arise that could affect you. The return of the warranty registration card is not a condition for warranty 

coverage.
Because of continuing product improvement, these specifications are subject to change without notice.

If you have other questions or need replacement parts, contact our  

Customer Service Hotline at (800) 229-5647 or  

visit our website at www.sureheat.com.

SHM International Corp.  3140 Moon Station Road,  Kennesaw, GA 30144

 

RTP2011A

Summary of Contents for Premier Estate PEVFR18LP

Page 1: ...pliance CONSUMER Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manu factured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating plate This app liance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the ma...

Page 2: ...blow directlyintotheappliance Avoidanydrafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flamepatterns Alteredburnerpatternscan cause sooting WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this appliance Due to high temperatures the appliance should be located out of traffic and away from furniture and draper...

Page 3: ...y shutoff system The ODS shuts down the fireplace if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 If appliance keeps shutting off see Troubleshooting pages 19 through 21 11 Do not run appliance where flammable liquids or vapors are used or stored under dusty conditions 12 Do not use this appliance to cook food or burn paper or other objects 13 Never pla...

Page 4: ...uel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space Theinformationonpages4through6willhelpyouclassify your space and provide adequate ventilation WARNING This heater shall not be installed in a room or space unless the required volume of indoor ...

Page 5: ...outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Figure 2 Ventilation Air from Outdoors DETERMINING FRESH AIR FLOW FOR APPLIANCE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to ...

Page 6: ...does not meet the required volume for indoor combustion air combustion and ventilation air shall be provided by one of the methods described intheNationalFuelGasCode ANSIZ223 1 NFPA 54 the International Fuel Gas Code or applicable local codes CONTINUED VENTED OPERATION Note When used as a vented heater appliance must be installed only in a solid fuel burning fireplace with a working flue and const...

Page 7: ...ugh this is beneficial installing appliance in rooms without enough ventilation air may cause mildew to form CHECK GAS TYPE Use the correct gas type natural or propane LP for your appliance If your gas supply is not correct or if you do not know your gas type do not install appliance INSTALLATION ITEMS NEEDED Before installing appliance make sure you have the items listed below external regulator f...

Page 8: ...lator damage could occur For propane LP gas the installer must supply an external regulator The external regulator will reduce incoming gas pressure Youmustreduceincominggaspressuretobetween 11 and 14 of water If you do not reduce incoming gas pressure heater regulator damage could occur Install the external regulator with the vent pointing down as shown in Figure 4 Pointing the vent down protects...

Page 9: ...nd that you install a sediment trap in supply line as shown in Figure 5 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into appliance gas controls If sediment trap is not installed or is i...

Page 10: ... valve located on or near gas meter of natural gas or using compressed air 3 Check all joints from gas meter to equipment shutoff valve for natural gas or propane LP supply to equipment shutoff valve for propane LP Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once CONTINUED 10 OPTIONAL REMOTE CONTROL SET INSTALLATION AND OPERATION COMMUNIC...

Page 11: ...Figure 7 Log Placement Savannah Oak 18 ...

Page 12: ...Figure 8 Log Placement Savannah Oak 24 and 30 ...

Page 13: ...1 2 3 4 5 6 7 13 Log Placement Premier Estate 18 Figure 9 Log Placement Premier Estate 18 Logs ...

Page 14: ...14 1 2 3 4 5 6 7 8 Log Placement Premier Estate 24 Figure 10 Log Placement Premier Estate 24 Logs ...

Page 15: ...ch must be lighted by hand When lighting the pilot appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor Do not touch any electric switch do not Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions repair may result in a fire or explosion Use only your hand to push in or turn the If you ...

Page 16: ... pilot does not light no spark contact a qual ified service person or gas supplier for repairs Until re with match see Manual Lighting Procedure page 15 8 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop out when released contact a qualified service person or gas supplier for re for five 5 seconds see Figure 11 This w...

Page 17: ...command from any compatable remote control it captures the new address and then beeps 3 times to con firm the synchronization programming Side Slide Switch ON OFF Key Note BACKUP FUNCTION If the batteries in the transmitter Hand Set or rec eiver are low the appliance can be switched on man ually by moving the 3 position slide switch see Fig ure 14 to the ON position Replace or remove low batteries...

Page 18: ... and let cool Remove blockage Blocked burner flame holes will create soot MAIN BURNER BURNER FLAME PATTERN Figure 19 shows the correct burner flame patern Figure 20 shows the incorrect burner flame patern turn Gas Log Set off see Turning OFF the Ap pliance page 15 see Cleaning and Maintenance this page see Troubleshooting page 19 CLEANING AND MAINTENANCE WARNING Turn off Gas Logs and let CAUTION ke...

Page 19: ...create soot We recommend that you clean the unit every three months during operation and have TROUBLESHOOTING Note All troubleshooting items are listed in order of operation POSSIBLE CAUSE 1 Ignitor electrode positioned wrong 2 Ignitor electrode broken 3 Ignitor electrode not con nected to ignitor cable 4 Ignitor cable pinched or wet 5 Broken ignitor cable 6 Bad piezo ignitor REMEDY 1 Replace pilo...

Page 20: ...20 ...

Page 21: ...21 ...

Page 22: ...90945 8 Orifice NG 1 RMH 120 SP033 RMH 120 SP018 8 Orifice LP 1 RMH 120 SP051 RMH 120 SP049 9 Orifice Tube Main Burner 1 RMH 120 09003 RMH 120 09003 9 Orifice Tube Main Burner 1 RMH 120 09004 RMH 120 09004 10 Elbow 375 MNPT X 375 Flare 1 RMH 120 00062 RMH 120 00062 11 Adapter 375 MNPT X 5625 Flare 1 RMH 120 00050 RMH 120 00050 12 Adapter 375 FNPT X 5625 Flare 1 FCHD1809021 FCHD1809021 13 Tube Main...

Page 23: ...roduce the specified heat propane LP gs supply may be low You may feel your gas pressure is too low If so contact your local natural or propane LP gas supplier Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty TECHNICAL SERVICE You may have further questions about installation opera tion or troubleshooting If so contact SHM Internat...

Page 24: ... rust or discoloring of any kind use or installation contrary to instructions and applicable building codes including heating the product to temperatures above its rated specifications which can cause considerable warping disassembly including removal of the product from a built in installation damage resulting from accident alteration misuse abuse hostile environments or improper installation repa...

Reviews: