Shut-Down Operation
CAUTION
• After the operation is shut down, please make sure that the flame is completely extin-
guished before leaving the place.
Observations
• To disconnect the power plug from the AC outlet, please make sure that the fan motor is stopped.
Turn “
OFF
” the operating switch, and the
heater flame will be extinguished, then the
fan motor will also automatically stop after
about three (3) minutes, and finally the oper-
ating lamp will turn off.
4
Inspection
• Before starting any inspection or service, to avoid electric shock, please make sure the
heater is shut down and that the power cord is disconnected.
• When cleaning the heater, please wear gloves to prevent possible injury.
CAUTION
3-4. Operation with Portable Generator
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
The heater operates within the voltage range
of 207 Volts to 253 Volts. Before plugging the
heater into the generator, the output voltage
of generator should be verified.
• Before operating the heater from a portable generator, please confirm that the generator
has been properly connected to the ground earth. To operate the generator without proper
grounding may result in electrical shock. Please refer to the owner’s manual supplied by
the generator’s manufacturer.
WARNING
If the voltage does not measure in this range,
the heater should not be plugged into the gen-
erator.
3-3. Use of the Heat Shielding Mat
To avoid unexpected fire or trouble, NEVER
use the heater on combustible flooring un-
less the heat shielding mat, which is avail-
able as an option, is used.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Heat shielding mat
Operating switch “
OFF
”
RU N
M I S F I R E
O F F
O N
8