English
8
Specifications
Model Number
VAL6KBE1S
Type
Radiated direct fired
Ignition System
High intensity discharge
Fuel
Kerosene or DIESEL
Fuel Consumption
3.21 /h 2.67kg/h
Heat Output
28,000 kcal/h 32.5kW
Tank Capacity
35
Continuous Operating Time
10 hours
Dimensions
815(H) x 655(W) x 732(D) mm
Disk Diameter 562 mm
Weight (Dry)
83.8 lbs, 38kgs.
Power Supply
AC230V (50Hz)
Power Consumption
• When igniting: 85 W
• When burning: 60 W
• Optional : +50W for Preheater
Electric Overload Fuse
1.6A
Noise Level (in operation)
69dB (A)
Safety System
• Flame Monitor (Flame Eye)
• Electric Overload System
Standard Parts
• Fuse x 2
• Filter Element x 2
• Nozzle x 1
• Nozzle Wrench x 1
• Oil Seal x 2
Wiring Diagram
2
Remove the nozzle using the nozzle wrench
provided as standard parts.
Replace with a new nozzle.
Loosen
Nozzle
3
Tighten the nozzle using the nozzle wrench
until the nozzle is fixed.
4
Put the burner assembly back with three nuts
removed.
PS
: Power Source
SW1
: Operation Switch
ALM
: Short
TH
: Thermostat
FE
: Photo Cell
FG
: Flame Grand
HT
: Open
FM
: Fan Motor
CM
: Open (Pre Heater)
IG
: Igniter
SP
: Solenoid Pump
RUN
: Running Lamp
MISFIRE
: Misfire Lamp
KA*
: Control Relay
F
: Line Fuse
ES
: Earthquake Sensor (Short)
MISFIRE
RUN
ALM
TH
CM
KAFM
PS
F
KASP
FE
SP
IG
FM
FG
HT
KAIG
SW1
ES
13