Press
to confirm input setting and save input setting into the memory. It will
switch to next item. If you did not change anything, press
to enter the next
item.
Press
to cancel input values and return to the setting screen. If you did not
change anything, press
to enter into next setting item.
4.3.3 Exit
Hold
for 1 second to return to default display.
If no input for 20 seconds, it will return to default display without saving changes.
4.3.4 Layer One Function List
Para. code
Functions
Value
Default/Range
Note
F.01
Blower suction time when lacking material.
Action code: S.02
10
seconds
5-127
seconds
-
F.02
Blending time
The blending time is set according to the material suction
time. It is calculated by the following formula: material
suction time
×
[F.02]%.
Set 0 to disable the function.
0%
no start
0-100%
-
F.03
Set blending times
Means to start blending once every time when certain times
of material suction is finished since startup.
If set it to be 1, it means blending material after every time
of material suction.
If no require of blending, set [F.02] to be 0.
1
time
1-9
times
-
F.04
Password Layer One
If [F.04] is not set as 0, the display will switch to [F.99] to
require input of correct password to enter [F.01]. If the
password is incorrect, the screen will return to default
display.
If it
’
s set to be 0, it means turn off the password setting.
0
0-999
-
Note: The password can be set by youself. Please contact us, if the
equipment is lockup by password.