26(33)
Note: The password can be set by youself. Please contact us, if the
equipment is lockup by password.
4.6 Description of Operation Procedures
4.6.1 Operation Procedures
The equipment is capable of working without keypad connected. The following is
about action codes.
Indicators
Action code
Operation procedures
Relative
parameter
Parameter
description
Default
Range
Red light
on
S. 01
Auto cleaning of filter
screen
F. 06
3
seconds
0-99
seconds
S. 02
Material suction
F. 01
10
seconds
5-127
seconds
Master batch suction
F.02
0%
0-100%
F. 03
3
1-9 times
S. 03
Auto cleaning of filter
screen;
Material starts to fall into
the material tank.
F. 07
3
seconds
0-99
seconds
S. 04
Wait for all materials to
fall into the material
tank.
F. 08
10
seconds
0-99
seconds
S. 05
Check alarm information
(instantly completed, no
display on control
panel.)
-
-
-
S. 06
Delay material
suction.
F. 05
0
seconds
0-999
seconds
Green light
on
-
Stand by
-
-
-