16(33)
air for cleaning will flow into auto dust cleaner (12) from the air pipe connector (14)
to clean the dust covering on the filter cloth and hopper inner wall. Then, the
blower will start again. When lacking materials, the alarm light (9) on control box
(11) will be on to sound an alarm. The equioment equipped with air acculamtor
can increase air storage capacity to reinforce the dedusting efficiency of the auto
dust cleaner.
2.2 Description of Electrical Components
2.2.1 Photoelectric Switch
1) It is applied to material conveying control and material shortage alarm for
SAL-U-E series.
2) Mounted on photosensor fixing plate.
Picture 2-3: Photoelectric Switch
2.2.2 Magnetic Proximity Switch
1) It is applied to material conveying control and material shortage alarm for
SAL-U-E series.
2) Mounted on photosensor fixing plate.
Picture 2-4: Magnetic Proximity Switch