45(51)
7~10 applied to molecular valve). Greasy dirt should be put into a
detergent solution with xylene. 15 minutes cleaning is suggested.
c. Take the rotor out of the liquid and let it rest with the channels vertically
for 5 minutes so the liquid can run out.
d. Blow off the residual liquid in the channels with compressed air.
e. Put the rotor back into the dehumidifier and run the unit with regeneration
circuit (the regeneration temperature between 50
℃
and 60
℃
) on for at
least one hour.
Note!
1. Note that in the dry air and wet air outlets, there will be high
concentrations liquid out for some time. If a solvent has been used,
there will be a residual smell for several days.
2. For some dirt which is greasy and sticky in the rotor, 100% elimination
is impossible. The only one thing you can do is to replace the rotor for
the cleaned rotor performance can only be recovered partly.
6.4 EGO
The EGO value has been setting before out factory, Don't modify it.
Picture 6-4: EGO
6.5 Cooler Clear Step
1) Disassemble the cooler's pipe and screw, and remove the cooler out of
the chiller.
2) Release the fixed screw on the upper and lower cover of cooler and
disassemble the cover.
3) Use brushes, compress ed air or low pressure water to clean the dust and
sundries on the cooler fan and copper pipe. Notes: water residue on the
Default Value
Drying
200
℃
Regenerating
200
℃