34(51)
Picture 4-16: Project Detection Time Setting Screen
Picture 4-17: Password Modification Setting Screen
Table 4-1: Project Setting Parameters
C
C
a
a
t
t
a
a
l
l
o
o
g
g
Parameter
Setting Range
Remark
Nor.
Set
(Normal
parameters
setting)
Three-phase detection
se (use~forbidden)
Open or close the onboard three-phase
detection
External startup
Forbidden (use~forbidden)
Use: The dehumidification and drying
system works when external start switch
input is effective.
Forbidden: external startup is forbidden.
[J3-10 input definition] Visible only when the
definition is
“
external startup and shutdown
”
Communication address
0
(
0~32
)
Address of communication devices
Baud rate
19200
(
4800/9600/19200
)
Communication Baud rate
Parity Bit
No parity (no parity, odd
parity and even parity)
Setting of parity bit
Stop bit
One stop bit (one stop bit,
two stop bits)
Setting of stop bit
Monitoring of drying heating
error
0m (0
~
999min)
Drying heating disconnection
Monitoring of regenerative
heating error
0m (0
~
999min)
Regenerative heating disconnection
Delayed overheat alarm
5s (0
~
999s)
Delayed time of overheat alarm