- 38 -
<Note>
•
Secure the drain valve body using a spanner or similar tool so that it does not
loosen when removing/installing the plug by turning it.
•
It is possible that there is a fuel or oil leak if the drained fluid contains oily
components. If this occurs, check for leakage locations.
•
Although the fluids that can leak internally consist of oil, fuel, cooling water and
battery fluid, the spill containment does not have a function that can separate
rainwater that has leaked into the equipment from these internally leaked fluids.
Properly dispose of liquid drained from the spill containment in a manner
according to the applicable laws and regulations.
(8) Cleaning/Inspecting the Spill Containment
Cleaning
Every 400 hours or 1 year
Caution: Injury
•
Always be sure to use the lifting lug when lifting the equipment, and lift slowly and
directly straight above.
•
Wear a helmet, safety shoes, gloves and similar protective gear when performing
lifting work. Do not stand or get under the equipment while it is suspended.
•
For cleaning/inspecting the spill containment, set this equipment with it situated on
a stable level surface so that it is prevented from moving.
1) Drain the liquid from the spill
containment.
2) Remove the seven installation bolts
(M8) of the spill containment.
3) Lift up the equipment body to separate
the spill containment and set the
equipment on a level surface.
4) Clean the inside of the spill containment
using a high-pressure washer or similar
equipment.
5) Drain the cleaning liquid from the spill
containment.
6) Remove any rust that has formed in the
spill containment and paint it again.
7) Pour water into the spill containment
and check that there is no leakage.
(After checking, drain the water you
have used.)
8) Install the spill containment to the
equipment in the reverse order of
removal.
<Note>
•
Do not operate the equipment with the spill containment separated.
•
If liquid drained from the spill containment during cleaning contains oily
components, dispose of it in a manner according to the applicable laws and
regulations.
•
If the spill containment has a leak, request repair at the retail outlet where the
equipment was purchased.
Bolt (M8)
- Right: 4 bolts
- Left: 3 bolts
Plug
Lifting Lug
This Equipment
Spill Containment