- 20 -
1.
8. Operating Procedures
Warning: Suffocation from Exhaust Fume
Do not operate the equipment in a poorly-ventilated area such as indoors or within a
tunnel because the engine exhaust fume includes components that are harmful to
humans.
Warning: Fire
Keep any ignitable items (such as fuel, gas and paint) or inflammable items away
from the equipment because the muffler, exhaust fume and other parts attain high
temperatures.
Provide at least 1 meter (3 feet) of distance between the equipment and walls and
other obstacles, and operate the equipment on a flat surface.
Caution: Suffocation from Exhaust Fume
Do not direct the engine exhaust towards passersby, private homes or similar
persons/locations because the engine exhaust fume includes components that are
harmful to humans.
Caution: Burn
The engine, muffler and similar parts are extremely hot during operation and
immediately after stopping the equipment. Never touch hot parts.
Caution: Injury
Use this equipment with it situated on a stable level surface so that it is prevented
from moving.
Do not move the equipment during operation.
Always be sure to turn off the switches of all devices using the equipment and turn
off the equipment circuit breakers before starting the engine.
Caution: Damage to the equipment or other properties
Do not use anything other than the specified optional device because they may cause
malfunctions.
<Note>
Check that the surrounding area is safe before starting the engine.
When there are multiple workers who are working together, they must mutually signal
each other before starting the engine.
Do not use in an area with high temperature or humidity, or an area with a large
amount of dust.
Do not open any doors during operation. Operating with a door open can negatively
affect cooling effect, resulting in an equipment malfunction.
Use ear protection if the level of noise is high. Failure to do so could result in hearing
damage.
8-1. Starting the Engine
1)
Turn all connected equipment’s switches to “OFF”.
2)
Turn all breakers (1-P 110V and 3-P 415V) to "OFF".
3)
Turn the fuel lever (on the fuel strainer) to "OPEN".
4)
Set the idle control switch to "ECO" or "AUTO".
5)
Check that the emergency stop switch has been released.
6)
If the temperature is 5°C or less, turn the starter switch to the
"PREHEAT" position and wait until the preheat lamp turns
off. (approx. 5 seconds)
7)
Turn the starter switch to the "START" position to start the
starter motor, which then starts the engine.
8)
After the engine starts, remove your hand from the starter
switch.
9)
Allow the engine to warm up for approximately 5 minutes.
Fuel Lever
(on fuel strainer)
Summary of Contents for DGW300MS/UKV
Page 2: ......
Page 11: ... 6 LABEL REPRODUCTION X505 011481 X505 011470 X564 000640 X564 000630 X505 006410 ...
Page 12: ... 7 X505 000240 X505 004890 X505 011490 X505 006430 M707 000260 M708 000890 ...
Page 39: ... 34 15 Engine Wiring Diagram ...
Page 40: ... 35 16 Generator Wiring Diagram ...
Page 41: ... 36 MEMO ...
Page 42: ... 37 MEMO ...
Page 43: ... 38 ...
Page 44: ... 39 2021 ...