- 19 -
7-4. Inspection for Fuel/Oil/Cooling Water Leakage
Warning: Fire
Absolutely never use the equipment if there is a fuel, oil or cooling water leak, and
be sure to always repair the leak before using.
Open the side door and check for fuel leakage from fuel line joints and similar
components, and check for oil and cooling water leakage. Open the fuel tap to perform
inspection and close it after inspection has been completed.
7-5. Battery Inspection
Warning: Injury to Eyes and Skin
Use protective gear, such as rubber gloves, when inspecting or replacing the battery
due to the dilute sulfuric acid in the battery fluid. Be sure that fluid does not contact
eyes, or on skin or clothing.
If battery fluid gets into the eyes, or on the skin or clothing, immediately wash with a
large amount of water, and always be especially sure to seek medical attention if it
gets into the eyes.
Warning: Explosion
Do not operate the equipment or recharge the battery when the battery fluid level is
below the lower level.
Do not generate any sparks near the battery and do not allow any fire or other open
flames or sparks near the equipment because the battery generates ignitable gas.
1)
Inspect the battery fluid level. If it is near the lower
level, add distilled water until it reaches the upper
level.
2)
Inspect for loose terminals and retighten if loose.
<Note>
It is necessary to recharge the battery when the
specific gravity of the battery fluid is 1.23 or less.
Contact the retail outlet where the equipment was
purchased if this occurs.
Battery Replacement Procedures
1)
Removed the front panel and under plate.
(M6 bolt x 2)
2)
Remove the "
-
" (negative) cable.
(Always be sure to first remove the "
-
" (negative)
side.)
3)
Remove the battery hold-down clamp.
4)
Remove the “+” (positive) cable.
5)
Remove the battery.
* Install the battery by performing the above
procedures in reverse order.
(Always be sure to first attach the "+" (positive)
side.)
<Note>
Use the specified battery.< 46B24L > (Japanese Industrial Standard)
[
–
]Post
[
+
]Post
Hold-Down
Clamp
Under Plate
Terminal
UPPER
Level
LOWER
Level
Battery
Summary of Contents for DGW300MS/UKV
Page 2: ......
Page 11: ... 6 LABEL REPRODUCTION X505 011481 X505 011470 X564 000640 X564 000630 X505 006410 ...
Page 12: ... 7 X505 000240 X505 004890 X505 011490 X505 006430 M707 000260 M708 000890 ...
Page 39: ... 34 15 Engine Wiring Diagram ...
Page 40: ... 35 16 Generator Wiring Diagram ...
Page 41: ... 36 MEMO ...
Page 42: ... 37 MEMO ...
Page 43: ... 38 ...
Page 44: ... 39 2021 ...