- 21 -
<Note>
Do not crank the starter motor for 15 seconds or more continuously.
If repeating starter switch operation, wait 30 seconds or more between operations.
After the engine starts, do not turn the starter switch to "START" during operation.
Restarting after Stopping due to Running Out of Fuel
The equipment includes an automatic air-bleeding device. You can easily restart the
engine according to the following procedures even if the engine stops due to running
out of fuel.
Turn all breakers (1-P 110V and 3-P 415V) to "OFF".
Turn the starter switch to the "STOP" position.
Add fuel to the fuel tank.
Set the idle control switch to "ECO" or "AUTO".
Turn the starter switch to the "START" position and crank the starter motor for
approximately 10 seconds.
After the engine starts, remove your hand from the starter switch.
Wait for air to be completely bled from the fuel pipes and engine speed to stabilize
(approx. 1 minute).
*Engine speed is not stable until all air is bled from the fuel pipes.
<Note>
Do not switch the engine to high speed or apply any loads to it until all the air has
been bled from the fuel pipes (until speed is stable). Doing so can cause a
malfunction.
8-2. Stopping the Engine
1)
Turn all breakers (1-P 110V and 3-P 415V) to "OFF".
2)
Set the idle control switch to "ECO" or "AUTO".
3)
Allow the engine to cool down for approximately 5 minutes.
4)
Set the starter switch to "STOP".
5)
After the engine stops, turn the fuel lever to "CLOSE".
<Note>
Do not stop the engine while welding or using as an AC power source. Doing so can
cause a malfunction.
If the engine does not stop when the starter switch is set to "STOP", turn the fuel lever
to "CLOSE". The engine will stop a few minutes afterwards. If the engine does not
stop by starter switch operation, stop using the equipment and request repair at the
retail outlet where the equipment was purchased.
3-P 415V Breaker
1-P 110V Breaker
Preheat Lamp
Idle Control
Switch
Starter Switch
Emergency
Stop Switch
Summary of Contents for DGW300MS/UKV
Page 2: ......
Page 11: ... 6 LABEL REPRODUCTION X505 011481 X505 011470 X564 000640 X564 000630 X505 006410 ...
Page 12: ... 7 X505 000240 X505 004890 X505 011490 X505 006430 M707 000260 M708 000890 ...
Page 39: ... 34 15 Engine Wiring Diagram ...
Page 40: ... 35 16 Generator Wiring Diagram ...
Page 41: ... 36 MEMO ...
Page 42: ... 37 MEMO ...
Page 43: ... 38 ...
Page 44: ... 39 2021 ...