(5) Drain Water from Fuel Tank
Drain Water
Every 200 hours
①
Unscrew the fuel drain plug.
②
Reinstall the drain plug, after draining
water completely
<Caution>
Change the seal, whenever changing oil.
Seal Part No.: 6C090-58961 (Kubota)
(6) Changing Coolant/Water
Change
Every 2000 hours or 2 years
(Total Coolant/Water Capacity: about 2.8 litre, including sub tank cap. 0.6 litre.)
.
①
Remove the top plate.
②
Remove the radiator cap.
③
Loosen the coolant drain plug.
④
After draining all the coolant, reinstall the water
drain plug.
<Caution>
Change the seal, whenever changing coolant.
Seal Part No.: 6C090-58961 (Kubota)
⑤
Replace all the coolant in the sub tank.
⑥
Fill the coolant to the neck of the water
Inlet in the radiator.
⑦
Reinstall the radiator cap.
⑧
Install the top plate.