9-2. Output Limitation
Please refer to the following table, because electric tools and home appliances
cannot be judged only by the rated output or the power consumption due to the
efficiency and character of the components.
Applicable Load (For reference only)
Loads
Capacity (kW)
50Hz
60Hz
Electric Bulb, Heater, etc.
3.0
3.3
Electric Tools, etc
(Series Motor),
1.5
1.7
Mercury Bulb
(High Power Factor Type)
1.2
1.4
Submersible Pump, Compressor, etc
(Induction Motor)
1.2
1.4
<Caution>
Be sure to use the frequency designated in the load incorporated in mercury bulb or
induction motor.
The load incorporated in motor may require greater power than the rated power
consumption. Therefore, consult with our authorized distributor or our dealer to
clarify.
When connecting 2 sets or more, start the load one by one, do not start them
simultaneously.
When switching a Mercury bulb again, wait for 15 minutes (approximately) until it
cools down.
A mercury bulb may flicker.