46
Inner Element
Outer Element
Air Cleaner Cap
Vacuator Valve
Air Cleaner
Clip
PCV Filter Cover
Band
PCV Filter
(Oil Separator)
Element
PCV filter
(Oil Separator)
Cap
O-ring
Loosen
Tighten
(3) Replacing the PCV (Oil Separator) Filter
Replace
Every 500 hours
Remove the PCV filter bands and PCV filter cover.
Wipe clean around the PCV filter cap taking care so that no foreign particles entry.
Remove the PCV filter cap.
Remove the PCV filter element.
Install the new PCV filter element.
Install the PCV filter cap.
Install the PCV filter cover and bands.
< Note >
PCV filter part no.: 8980305320 (Isuzu part no.)
(4) Air Filter Element Cleaning/Replacement
Remove the air cleaner clips and cleaner cap.
Remove the outer element.
Clean or replace the outer element. Replace by
performing the above procedures in reverse order.
< Note >
Inner air element must not be reused even if it is cleaned.
Replace the inner element when replacing the outer element.
Always be sure to turn the cleaner cap in the direction
indicated by the arrow.
Replace the elements earlier if using in an excessively dusty
location.
Do not add oil as this generator uses a dry element.
Clear foreign material by pinching the vacuator valve once a
week in normal operating conditions or daily if operating in a
location that is excessively dirty or dusty. Wipe away any dirt
or moisture that has adhered to the parts.
Never touch the elements for any reason except cleaning.
Clean (Outer element)
Every 250 hours
Replace (Inner / Outer element)
Every 500 hours