18
■
DEF Indicator Lamp Action
LAMP
State
DEF
EXH.
SYSTEM
NO POWER
(
SHUTDOWN
)
ENGINE
ESCAPE
MODE
Stage-
Ⅰ
Warning
○
(Turn ON)
○
(Turn ON)
-
○
(Turn ON)
-
Stage-
Ⅱ
Early Inducement
○
(Slow Blinking)
○
(Turn ON)
-
○
(Turn ON)
-
Stage-
Ⅲ
Final Inducement
(
Engine Shutdown
)
○
(Quick Blinking)
○
(Turn ON)
○
(Turn ON)
○
(Turn ON)
-
ESCAPE MODE
○
(Quick Blinking)
○
(Turn ON)
-
○
(Turn ON)
○
(Turn ON)
(4) Operating Escape Mode
This mode allows you to restart the engine that forcibly shut down due to DEF shortage or SCR
system error.
A total of 30 minutes of time operation is possible for urgent needs.
Set the ACCESSORY switch to ON position.
Loosen the knob on the operation panel and
open the panel.
Press the Escape Mode switch (blue button) in
the control box. (Make sure that the escape
mode lamp is lit.)
Close the operation panel and tighten the knob.
Set the ACCESSORY switch to OFF, and use
the safety cap to cover it.
Set the STARTER SWITCH selector to START
position.
< Note >
ESCAPE MODE is available for total up to 30
minutes. On and after 30 minutes, the procedure
above described is never applicable, and the engine
never restarts.
Upon completing repair during ESCAPE MODE, it
automatically switches back to the normal mode.
5-6. Meters and Gauges
Engine Meters and Gauges
(1) Hour Meter
Displays the operating time. Use this as a reference for managing
periodic inspection interval. Be careful as the hour meter operates
when the ACCESSORY switch is at ON position regardless of engine
is running or not, and / or when the engine shuts off abnormally when
STARTER SWITCH is set at START position or AUTO position
(Except when Over Crank Indicator illuminate or flashing).
1
2
3
4
5
6
Control Box
Operation Panel
Knob
Escape Mode Switch
(Blue Button)