STOP DISTANCE
The Stop Distance parameter defines the position of the labels at the
peeler plate. It references the position from which each dispensing cycle
is started.
The “Label‑Teach” function learns the movement to determine the exact
pre‑dispensing position. Refer to Label‑Teach operation further in this
chapter.
a
Min Value: 0 (steps); Max Value: 99999 (steps)
a
Default setting: 100
a
Setting is retained when power is turned off.
Lead
– Initiates timing on the leading edge of the product.
Trail
– Initiates timing on the trailing edge of the product.
COMPENSATION SPEED
The Compensation Speed parameter defines the maximum motor speed
for the synchronous dispensing operation.
a
Min Value: 1 (Hz); Max Value: 99999 (Hz)
a
Default setting: 10000
The default value should not be changed unless authorized by manu-
facturer.
+
STOP DISTANCE
+00000 [Steps]
PARAMETER - WIPE
-EXIT
ENTER
SCRUP SCRDN
+
COMPENSATION SPEED
+10000 [Hz]
PARAMETER - WIPE
-EXIT
ENTER
SCRUP SCRDN