L500A V2 High Speed Labeler Manual
34
35
Setup
The sensor is stable and should not require re‑adjustment after the first
initial setup unless there is significant change in the shape and/or thick‑
ness of the label, or changes in power supply voltage.
Step 1. Remove all material from sensor.
Step 2. Gain Adjust.
Center "GAIN ADJUST" (see Figure 4‑10) ‑ Turn GAIN
ADJUST four (4) turns counter‑clockwise, then turn GAIN ADJUST two
(2) turns clockwise.
Figure 4-10. Retroreflective Mode Alignment
G A IN
A D J U S T
Z E R O
A D J U S T
4X
GAIN ADJUST
ZERO
ADJUST
Step 3. Zero Adjust.
Set ZERO ADJUST to the point where the ZERO light
just begins to come on. It is not important if the light is on or off ‑ what
is important is that the light is very near the point where it changes from
off to on.
Summary of Contents for L500A V2
Page 12: ...L500A V2 High Speed Labeler Manual 12 Notes ...
Page 14: ...L500A V2 High Speed Labeler Manual 14 Notes ...
Page 22: ...L500A V2 High Speed Labeler Manual 22 Notes ...
Page 50: ...L500A V2 High Speed Labeler Manual 50 Notes ...
Page 80: ...L500A V2 High Speed Labeler Manual 80 Notes ...
Page 84: ...L500A V2 High Speed Labeler Manual 84 Notes ...
Page 89: ...89 Appendix Figure 8 1 Wiring Diagram 8 ...
Page 90: ...L500A V2 High Speed Labeler Manual 90 Figure 8 2 Wiring Diagram ...