Chapter 5 Operator Interface
Figure 5-7. Tamp-On Screen
How the adjust keys work:
a
MOMENTARILY
Push the or ‑ key momentarily advances the selected
parameter by one increment.
a
HOLD
Push and hold the or ‑ key advances the selected param‑
eter slowly.
a
HOLD 5 seconds
Push and hold the or ‑ key for 5 seconds will advance
the selected parameter fast.
Note: It is recommended to set the delay in the parameter menu first
as close as possible to the desired position. Especially when there is a
high encoder line count the change of the label position on the product
is minimal for a single encoder increment and it will take a long time to
adjust the label position.
Operational Modes:
Tamp-On, Blow-On, and
Tamp-Blow
Using the main screen, different operating modes
can be chosen: Tamp‑On, Blow‑On, Tamp‑Blow
or Wipe‑On (previously discussed.)
BLS 2020 M188
MENU MODE
- TAMP ON -
STOP _ _ _ _
Operational
Mode
_ _ _ _
+ 0 MISSING LABELS
Stops
Tamp
Mode