Section 9 Periodical inspections and service
51
3. Oil and water supply list
Oil
maintenanc
e item
O
il t
ype
Q
uant
ity
of
oil
Ins
pec
tion/
oiling
int
er
val
Replac
ing
int
er
val
Se
rvi
ce
point
①
Implement (reel) C.G.
50
40
②
Cylinder C.C.
50
10
③
Lift arm
C.G.
50
15
④
Hydraulic oil
transmission
G.O. 32 50
600 1
⑤
Rear axle case
G.O.
1.3
50
600
1
⑥
Rear axle final
G.O.
0.5
50
600
2
⑦
Hydraulic oil tank G.O.
38
50
600
1
⑧
Fuel tank
F.
42
Before starting
operation
1
⑨
Engine oil
E.O.
5.5
50
100
1
⑩
Radiator W.
6.5
Before starting
operation
1
⑪
Steering system
C.G.
50
2
⑫
Pedal shaft
C.G.
50
5
⑬
Battery D.W.
50
1
Oil used
E.O.
Diesel engine oil
All season, SAE10W/30
–5
℃
~25
℃
: SAE20W
10
℃
~35
℃
: SAE30
G.O.
HST oil, equivalent to ISO VG46
C.G.
Chassis grease or universal
grease No.2
F: Light oil
W: Coolant
D.W: Distilled water
Cautions:
Change both E.O and G.O after
the initial 50 hours of
operation.
When supplying oil, stop the
engine and keep away a fire.
If opening the radiator cap while
the engine is hot, be careful
sufficiently.
Supply oil to pins and links other than above ones as required.
●
Supply oil to each linkage other than above ones as required.
Shibaura Europe BV
All manuals and user guides at all-guides.com