Detailed Function Description
39
frequency source Y
”
.
P0-020
Control mode of terminal
Setting range
:
0
~
3
Factory value
:
0
0: 2-wire mode1
;
1: 2-wire mode 2.
2: 3-wire mode 1
;
3: 3-wire mode 2.
2-wire run mode only need to connect two signals: Forward run and
reverse run.
K1
Forward run
2-wire mode 1
2-wire mode 2
K2
K1 K2 Run command
K1 K2
Run command
Reverse run
COM
OFF OFF
stop
ON OFF
Forward
OFF ON
Reverse
ON ON
stop
OFF OFF
Stop
ON OFF
Forwaed
OFF ON
Stop
ON ON
Reverse
Chart 5-3 Diagram of two-wire run mode
3-wire run mode need to connect three signals: Forward run,
reverse run, 3-wire run assistant.