MX-FXX1 SIMULATIONS, FAX SOFTWARE SWITCH 5 – 39
61
1-8
Setting of DTMF
minimum pause time
This sets the minimum pause time between DTMF signals when
sending DTMF signals.
Minimum pause time can be set by binary inputting N over the range of
0 to 255 (1ms x N).
Setting can be made over the range of 50ms to 255ms in 1ms
increments by binary inputting.
The initial value is reverted to if a value outside of the setting range is
set.
0
120ms
Adjustment
value
1
1
1
1
0
0
0
62
1-5
DTMF signal send time
This sets the time that DTMF signals are sent when sending DTMF
signals.
Send time can be set over the rage of 70 to 310ms in 10ms increments
by binary inputting N from 0 to 31 (110ms x N).
The initial value is reverted to if a value outside of the setting range is
set.
0
110ms
1
0
1
1
6
Not used
0
Refer to "SW62, 6 Initial
value"
7
DPMUTE control
This sets whether or not to control the ports when sending the dial
pulse.
If the dial pulse dialing meets the difficulties, the setting must be
changed.
Functions only in Australia, New Zealand, U.K., France, Germany,
Sweden.
"0": OFF
"1": ON
0
OFF
8
Busy tone OFF non-
detection time
This sets the non-detection time on the busy tone OFF section.
Change the setting in cases where noise, etc. on the busy tone ON
section adversely affects the ON section.
"0": 100ms
"1": 300ms
* Make shorter than the "busy tone OFF detection time."
0
100ms
63
1-2
Lower limit of busy
tone ON detection time
This sets the lower limit time of the ON section when detecting
frequency of the busy tone signal.
If busy tone signals are not detected in excess of this time, do not count
as 1 pulse.
"00": 250ms
"01": 140ms
"10": 450ms
"11": 350ms
0
250ms (North America/
Australia/New Zealand/
China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle
East/Other3/South Africa)
0
0
140ms (U.K./France/
Germany/Sweden/
Finland/Norway/Denmark/
Netherlands/Italy/
Switcherland/Austria/
Slovakia/Rusia/Spain/
Portuguese/Luxemburg/
Belgium/Czech/Hungary/
Greece/Poland)
1
3-4
Upper limit of busy
tone ON detection time
This sets the upper limit time of the ON section when detecting
frequency of the busy tone signal.
If busy tone signal is detected in excess of this time, do not count as 1
pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
0
"00": 750ms
(North America/U.K./
France/Germany/Sweden/
Finland/Norway/Denmark/
Netherlands/Italy/
Switcherland/Austria/New
Zealand/China/Indonesia/
Thailand/Malaysia/
Philippine/Hong Kong/
Taiwan/Middle East/
Slovakia/Other3/Rusia/
Spain/Portuguese/
Luxemburg/Belgium/
Czech/Hungary/Greece/
Poland)
"10": 1000ms
(Australia/India)
"11": 2850ms
(Singapore/South Africa)
0
SW62, 6 Initial value
"0": North America/Australia/China/Singapore/Indonesia/Thailand/Malaysia/India/Philippine/Hong Kong/Taiwan/Middle East/Other3/Rusia
"1": U.K./France/Germany/Sweden/Finland/Norway/Denmark/Netherlands/Italy/Switcherland/Austria/New Zealand/Slovakia/South Africa/Spain/Portuguese/
Luxemburg/Belgium/Czech/Hungary/Greece/Poland
SW
No.
Bit
No.
Item
SW selection and function
Initial value
System
settings
Summary of Contents for MX-FXX1
Page 76: ...Memo ...
Page 77: ...Memo ...