B. Special diagnostics mode
To execute the special diagnostics, the machine must enter the nor-
mal diagnostics mode first.
At the normal mode home position (with "PCU DIAG MODE XX"
displayed), turn on the LINE (ONLINE) key and the ENTER (SET) key
simultaneously, then turn off them, and the machine will enter the
special diagnostics mode.
Immediately after entering the special diagnostics mode (at the home
position), "PCU DIAG SPECIAL" is displayed.
To cancel the special diagnostics mode, return to the home position
with the MENU key (where "PCU DIAG MODE SPECIAL" is dis-
played), and press the FORM FEED (PAPER EXIT) key to return to
the normal mode home position (where "PCU DIAG MODE #" is
displayed).
Then press the FORM FEED (PAPER EXIT) key again to return to
the normal print mode.
(When "PCU DIAG SPECIAL" is displayed, the special mode items
can be selected with the MENU key.)
(1) The consumable parts counter value and the
error counter value can be checked.
Each color toner concentration level can be displayed.
Each color print density level can be displayed.
Time-out time can be displayed.
The above values can be set to desired values.
a. Menu display
COUNTER SET2 XXX
b. Details
Use the MENU key to select the items of COUNTER SET2 XXX.
(When "PCU DIAG SPECIAL" is displayed, the special mode items
can be selected with the MENU key.)
The counter kind can be selected with the
v
key and the
w
key.
After selecting the counter kind, press the ENTER (SET) key to dis-
play the selected counter value.
Under this state, press the RESET key to return to the counter kind
selection mode.
When the counter value is displayed, use the
v
key and the
w
key to
change the counter value. To select the digit to change, use the
MENU key.
To register the changed counter value, turn on the manual paper feed
detector and press the FORM FEED (PAPER EXIT) key at the same
time.
Immediately after the counter value is changed, the display returns to
the counter kind selection mode.
(Each color print counter, error counter)
DISPLAY
Item
LEVEL 1
LEVEL 2
LEVEL 3
Total counter
(COUNTER SET2 TTL)
COUNTER SET2 TTL
TTL
XXXXXXXX
Yellow print quantity
COUNTER SET2 YPR
YPR
XXXXXXXX
Magenta print quantity
COUNTER SET2 MPR
MPR XXXXXXXX
Cyan print quantity
COUNTER SET2 CPR
CPR XXXXXXXX
Black print quantity
COUNTER SET2 KPR
KPR
XXXXXXXX
Jam counter
COUNTER SET2 JAM
JAM
XXXXXXXX
Scanning unit error counter
COUNTER SET2 OPC
OPC XXXXXXXX
Main motor error counter
COUNTER SET2 MAM
MAM XXXXXXXX
Scanning motor error counter
COUNTER SET2 PLM
PLM
XXXXXXXX
Abnormally high fusing temperature error counter
COUNTER SET2 HLM
HLM XXXXXXXX
Abnormally low fusing temperature error counter
COUNTER SET2 HLL
HLL
XXXXXXXX
Fusing section thermistor error counter (Open)
COUNTER SET2 THO
THO XXXXXXXX
Developing motor error counter
COUNTER SET2 DVM
DVM XXXXXXXX
SHARP SERVICE MANUAL JX8200SM [10] DIAGNOSTICS
10 – 13