6 - 7
Ex. 3 Measurement 1 Point sensor
• 8 points are handled by 1 byte.
• Black & white = FA
(H)
F
A
1
1
1
1
1
0
1
0
Point No.
P7
P6
P5
P4
P3
P2
P1
P0
Black & white White White White White White Black White Black
0 = Black, 1 = White
[Example of HMI]
2) Measurement execution 2: code 0011
H
• Execute all of the measurement programs for a specified object type or corresponding
measurement program for the specified camera.
• The result data of the measurement program will be divided into packets by each 512 bytes
(128 data
×
4 bytes) from the beginning, and sent as the response.
[Command]
Execution
:
Station No.
0
0
1
1
Object type camera
SC SC CR
(H ) (L ) No.
(H ) (L )
[Output data (general purpose serial)]
F C1 BRT
Packet 0 Measurement 1
Registration 0 ~7
1 bytes
Registration 8 ~ 15
1 bytes
•
The first measurement execution command is specified as "0" for the specified packet No.
[Response]
:
Station No.
0
0
1
1
RC RC RC RC
(H )
•••
•••
(L ) (H ) (L )
Execution
Object type camera
No.
•
Current packet No.,
Final packet No.
Numeric value result
SC SC CR
data
(H ) (L )