6 - 13
4) Parallel input instruction: codeF004
H
• Output the preset data (ON/OFF) to the parallel I/O terminal block (16 terminals).
[Command]
:
Station No.
F
0
0
4
D0 D1
•••
•••
D15
SC CR
(H ) (L )
• Output data D0 to D15: 0 = OFF, 1 = ON
:
Station No. F
0
0
4
RC RC RC RC SC SC CR
(H )
•••
•••
(L ) (H ) (L )
[Response]
5) Setting gain/offset: code F005
H
• Change the gain (contrast) and the offset (brightness) of the specified camera
[Command]
:
Station No. F
0
0
5
Preset value
SC SC CR
10
2
10
1
10
0
(H ) (L )
•
Camera No.: 0 =Camera 1, 1 = Camera 2
•
gain/offset setting: 0 = gain, 1 = offset
• Preset value: 0 to 255
[Response]
:
Station No. F
0
0
5
RC RC RC RC SC SC CR
(H )
•••
•••
(L ) (H ) (L )