5 - 3
Specifications
Item
Power supply input
Parallel interface
Power supply voltage / power
consumption
Operation ambient
temperature / atmosphere
Storage ambient temperature /
atmosphere
Outside dimension/weight
Lighting
control
0 to 45
°
C / 35 to 95% RH (no condensation)**
24V DC (
±
10%) 30W
-20 to 70
°
C / 35 to 95% RH (no condensation)
81mm (W)
×
176.4mm (H)
×
126.4mm (D)
(protruding portions are not included)
Operation input
Image output
Touch panel, and commercially available USB mouse (*)
Input common 1 point
Interrupt input (trigger) 1 point
Output common 1point
Input 15 points
READY 1 point
HALT output 1 point (interlocking with watchdog timer)
Output 16 points
IPU external
interface
Extension terminal
Input 16 points (X0 to X15) 12/24V DC 7mA (24V DC)
Output 16 points (Y0 to Y15) 12/24V DC 80mA (open corrector)
Trigger input (parallel interface), serial trigger, and manual trigger
(for testing)
+24V, 0V
FG
Parallel interface
Serial interface
RS-232C/RS-422 (2-wire system only) used for lighting control
RS-232C/RS-422 (2-wire system/4-wire system) (2.4 to 115.2kbps)
upward calculator, PLC
Measurement
start input
CCD trigger
Internal trigger
External trigger
Dimmer function, lamp ON/OFF (LED), shutter ON/OFF (halogen)
4 systems, 2 controls/1 system
RS-232C/RS-422
Control function
Number of control
Control port
HMI External
interface
USB 1.1 specification, 2 channel (power supply capacity 100mA / ch)
10/100 base-TX
VGA output port 1 point, IV LCD monitor output 1 point
USB host
LAN
Cameras to be connected
IV-S30C1, IV-S30C2, IV-S30C3, and IV-S30C4
Image output
SVGA (800
×
600
×
24bpp) analog output
IV LCD monitor (800
×
600
×
18bpp) digital output
* Both can be used at the same time, but touch panel overrides the USB mouse.
**When this is used with the IV-08MP LCD monitor as one unit, temperature should be 0 to 40
°