6 - 9
5) Result data reading 1: code 0111
H
• Reads the numeric value result of the last measurement.
• The result data of the measurement program will be divided into packets by each 512 bytes
(128 data
×
4 bytes) from the beginning, and sent as the response.
[Command]
Execution
:
Station No. 0
1
0
RC RC RC RC Object type Camera
SC SC CR
(H )
•••
•••
(
(
L )
H ) (L ) No.
(H ) (L )
:
1
Numeric value result
data
:
Station No.
0
1
1
0
SC SC CR
(H ) (L )
•
The first measurement execution command is specified as "0" for the specified packet No.
[Response]
•
Current packet No.,
Final packet No.
:
Station No.
0
1
1
1
SC SC CR
(H ) (L )
6) Result data reading 1: code 0112
H
• Reads the arithmetic result of the last measurement.
• The result data of the measurement program will be divided into packets by each 512 bytes
(64 data
×
8 bytes, double precision floating decimal point) from the beginning, and sent as the
response.
[Command]
Execution
:
Station No.
0
1
1
2 Object type camera
SC SC CR
(H ) (L ) No.
(H ) (L )
:
Station No.
0
1
1
1
RC RC RC RC
(H )
•••
•••
(L ) (H ) (L )
Execution
Object type camera
No.
•
The first measurement execution command is specified as "0" for the specified packet No.
[Response]
•
Current packet No.,
Final packet No.
SC SC CR
(H ) (L )
Numeric value result
data