GX20
3 – 5
CONFIDENTIAL
[2] Disassembly and reassembly
•
To reassemble, follow the reverse procedure.
Figure 1
Figure 2
*
Be careful not to deform the electrostatic plate (PSLDC3348AFZZ)
used to eliminate static electricity when installing/removing the key
PWB.
STEP
REMOVAL
PROCEDURE
FIGURE
1
Back Cabinet
(Key) Ass’y
1.Battery Cover........
2.Li-Ion Battery.........
3.Screw Cover..........
4.Screw....................
5.Hook.....................
(A1)x1
(A2)x1
(A3)x2
(A4)x4
(A5)x5
1
2
Key PWB-B
1.Socket...................
2.Solder....................
3.Hook.....................
(B1)x2
(B2)x7
(B3)x4
2
Back Cabinet (Key)
Ass'y
(A1) x 1
(A2) x 1
(A4) x 2
Ø1.7 x 5 mm
(A4) x 2
Ø1.7 x 5 mm
(A3) x 2
(A5) x 5
Back Cabinet (Display) A'ssy
(B1) x 1
(B2) x 2
(B2) x 2
(B1) x 1
Relay FPC_C
PWB-E
Back Cabinet (Display) A'ssy
Electrostatic
plate (Inside) *
(B3) x 4
Key PWB-B
Cover, External Connector
Cover, Jack
(Hands Free)
Keys, Side
(B2) x 1
(B2) x 2
Relay FPC_B
PWB-D
Relay FPC_A
PWB-C
Flexible PWB,
Side Switch
PWB-I