FO-DC600U
2 – 31
SW38 No. 1 ~ No. 4 Reserved
Set to "0".
SW38 No. 5 ~ No. 8 Distinctive ringing
When the ringing setting is turned off, all of the CI signal are received.
When any of the standard, and ring patterns 1 through 3 is selected for
the ringing setting, only the selected CI signal is received.
CI signal patterns
The CI signal patterns consists of the standard pattern, and ring pat-
terns 1 through 7. The standard pattern is the conventional one.
SW43 No. 4 ~ No. 6 Busy tone detection frequency
To select frequency range of signals to be detected as Busy Tone.
SW43 No. 7, No. 8 Reserved
Set to "0".
SW44 No. 1 ~ No. 3 Service condition for line-2
000: Transmission is enabled. Reception mode is auto.
001: Transmission is enabled. Reception mode is manual only.
010: Transmission is disable. Reception mode is auto.
SW44 No. 4 ~ No. 8 Reserved
Set to "0".
SW45 No. 1 ~ No. 6 Reserved
Set to "0".
SW45 No. 7 Reserved
Set to "1".
SW45 No. 8 Reserved
Set to "0".
SW46 No. 1 ~ No. 8 Reserved
Set to "0".
SW47 No. 1 ~ No. 4 Reserved
Set to "0".
SW47 No. 5 Reserved
Set to "1".
SW47 No. 6, No. 7 Reserved
Set to "0".
SW47 No. 8 Reserved
Set to "1".
SW48 No. 1 Reserved
Set to "1".
SW48 No. 2, No. 3 Reserved
Set to "0".
SW48 No. 4, No. 5 Reserved
Set to "1".
SW48 No. 6, No. 7 Reserved
Set to "0".
SW48 No. 8 Reserved
Set to "1".
SW49 No. 1 Reserved
Set to "1".
SW49 No. 2, No. 3 Reserved
Set to "0".
SW49 No. 4, No. 5 Reserved
Set to "1".
SW49 No. 6, No. 7 Reserved
Set to "0".
SW49 No. 8 Reserved
Set to "1".
SW50 No. 1 ~ No. 7 Reserved
Set to "0".
SW50 No. 8 Reserved
Set to "1".
SW51 No. 1 ~ No. 8 Reserved
Set to "0".
SW52 No. 1 ~ No. 8 Reserved
Set to "0".
SW53 No. 1 ~ No. 8 Reserved
Set to "0".
SW54 No. 1 ~ No. 8 Reserved
Set to "0".
SW55 No. 1 ~ No. 8 Reserved
Set to "0".
SW56 No. 1 ~ No. 8 Reserved
Set to "0".
SW57 No. 1 ~ No. 8 Reserved
Set to "0".
SW58 No. 1 ~ No. 8 Reserved
Set to "0".
2S
4S
1.5S
3S
1S
4S
1.5S
4S
0.8S
4S
0.3S
4S
0.4S
4S
1S
3.5S
0.5S
3S
0.5S
3S
2S
2S
0.5S
0.5S
1S
0.2S
0.8S
0.4S
0.3S
0.2S
0.4S 0.8S
0.2S 0.2S
1S
0.5S
1S
0.5S
0.5S
0.5S
0.5S
1S
0.5S
0.5S
STANDARD
RING
PATTERN 1
for USA
RING
PATTERN 2
for USA
RING
PATTERN 3
for USA
RING
PATTERN 1
for CANADA
RING
PATTERN 2
for CANADA
RING
PATTERN 3
for CANADA
1S
3S
1S
RING
PATTERN 4
for USA
1S
SW39 No. 1 ~ No. 7 Reserved
Set to "0".
SW39 No. 8 Reserved
Set to "1".
SW40 No. 1 Reserved
Set to "1".
SW40 No. 2 ~ No. 4 Reserved
Set to "0".
SW40 No. 5, No. 6 Reserved
Set to "1".
SW40 No. 7, No. 8 Reserved
Set to "0".
SW41 No. 1 Reserved
Set to "1".
SW41 No. 2 ~ No. 4 Reserved
Set to "0".
SW41 No. 5 Reserved
Set to "1".
SW41 No. 6 ~ No. 8 Reserved
Set to "0".
SW42 No. 1, No. 2 DTMF detection time
Used to set detect time of DTMF (Dual Tone Multi Frequency) used in
remote reception (5
). The longer the detection time is, the error
detection is caused by noises.
SW42 No. 3 ~ No. 8 Reserved
Set to "0".
SW43 No. 1 ~ No. 3 Reserved
Set to "0".
Summary of Contents for FO-DC600
Page 98: ...FO DC600U Control PWB parts layout Top side 6 16 F1 F2 F5 ...
Page 99: ...FO DC600U Control PWB parts layout Bottom side 6 17 F100 F101 F102 ...
Page 101: ...FO DC600U LIU PWB parts layout Top side 6 19 ...
Page 102: ...FO DC600U LIU PWB parts layout Bottom side 6 20 ...
Page 105: ...FO DC600U Printer PWB parts layout Top side 6 23 ...
Page 106: ...FO DC600U Printer PWB parts layout Bottom side 6 24 ...