LC-32/40/46LE600E/RU/S
4 – 8
10. White Balance Adjustment
Adjustment gradation values (INFO) appear on page 8/8 3-4 lines of process adjustment, and adjustment initial values (offset value) appear on pages
8/8 5-10 lines. For white balance adjustment, adjust the offset values on pages 8/8 5-10 lines.
1. Preparation
1) Luminance meter reference device :Minolta CA-210
2) Condition of the unit for adjustment and inspection:Modulated light: MAX (+16)
2. Setting
1) The luminance meter is set to the center of the screen of the set.
2) In “INCH SIZE” on the process adjustment page 1/8, sets it to the size of each panel with the / key to R/C.
3. Adjustment method
Check that the values of point A and B on page 8/8 of process adjustment are set as below. If not, change them accordingly.
1) Display the current adjustment status at point B. (Page 8/8 of process adjustment)
The display for checking the adjustment status is toggled by pressing the “OK” button on the remote control.
(Normal OSD display
→
“B”
→
display for check (OSD disappears)
→
“B”
→
normal OSD display
→
...)
2) Read the value of the luminance meter.
3) Change Point B ADJ R/Point B ADJ B (Adjustment offset value) on page 8/8 of process adjustment so that the values of the luminance meter
approach x = 0.272 and y = 0.277.
(Basically, Point B ADJ G is not changed.)
4) Follow Point A as well as item 3).
Change Point A ADJ R/Point A ADJ B (Adjustment offset value) on page 8/8 of process adjustment so that the values of the luminance meter
approach x = 0.272 and y = 0.277.
5) Select “WB WRITE” on page 8/8 in the process, set “YES”, and press the OK key of remote control.
The adjustment value is written. and then shut down the AC power.
* Initial value of RGB of point B: 3712
* Initial value of RGB of point A: based on calculated of each G point
6) [Adjustment value]
* Teaching set send by engineering dept is set as reference
4. Adjustment reference standard value
WB Point A
1280
WB Point B
3712
Level
Spec Data
Adjustment Spec
Inspection Spec
Point A ref. value
Point B ref. value
1280
3712
x=0.272
y=0.277
x=0.272
y=0.277
±
0.001
±
0.002
±
0.002
±
0.004
Adjustment spec
±
0.004
Adjustment spec
±
0.002
Inspection spec
±
0.006 (point 1)
Inspection spec
±
0.004 (Excluding the above-mentioned)
Summary of Contents for Aquos LC-32LE600E
Page 50: ...LC 32 40 46LE600E RU S 6 4 2 2 IC1302 VHiMT8292N 1Y 2 2 1 Block Diagram ...
Page 62: ...LC 32 40 46LE600E RU S 6 16 2 12 IC8401 RH iXC721WJQZQ 2 12 1 Block Diagram ...
Page 75: ...LC 32 40 46LE600E RU S 7 2 2 OVERALL WIRING DIAGRAM LC 40LE600E RU S ...
Page 76: ...LC 32 40 46LE600E RU S 7 3 3 OVERALL WIRING DIAGRAM LC 46LE600E RU S ...
Page 77: ...LC 32 40 46LE600E RU S 7 4 4 SYSTEM BLOCK DIAGRAM LC 32LE600E RU S ...
Page 78: ...LC 32 40 46LE600E RU S 7 5 5 SYSTEM BLOCK DIAGRAM LC 40LE600E RU S ...
Page 79: ...LC 32 40 46LE600E RU S 7 6 6 SYSTEM BLOCK DIAGRAM LC 46LE600E RU S ...
Page 95: ...LC 32 40 46LE600E RU S 9 12 ...