User’s guide
HRK 65-125
-
13
-
HS
Installation
6.1
ASSEMBLY
1.
Remove packaging and blocking of top frame.
2.
Place the machine on a level floor with sufficient space around and above the
machine.
3.
Ensure there is adequate ventilation and lighting at the workplace.
4.
Avoid draughts, in order to prevent uneven heating.
6.2
CONNECTING AIR/TIMER UNIT
A black tube that is coming out of the machine has one air tube. Connect the tube to the
corresponding number of the air/timer unit (at the backside).
6.3
CONNECTING FOOT SWITCH
Connect the plug of the foot switch on the corresponding socket (a) at the front side of
the timer unit. See 5.2
6.4
CONNECTING COMPRESSED AIR
1.
Check that all heating elements and pressure bars in the top frame are firmly
attached.
2.
Using a quick-action coupling connect the rear of the machine to your compressed
air system or compressor.
6.5
CONNECTING POWER
1.
Check that all switches of the control units are in the 0-position.
2.
Put the plug into the socket.
6