15
Product Version 1.0 | Revision A | Released 2023-01-10
VP CONNECTOR
The VPL Series has a female multi-core 8 pin cable located in the first end of the VPL, and a male multicore 8 pin
connector in the last end of the VPL. The 8 pins are divided by 1xShield, 3xPower, 4xSignal (see figure 18).
Figure 18: VPL female connector
The fixture must be grounded/
earthed and be able to be isolated
from AC power. The AC power
supply must incorporate a fuse or
curcuit breaker for fault protection.
Color
Black
White
green/yellow
Conductor
live
neutral
ground (earth)
Symbol
or
L
N
Wire
The power cable color coding:
• Connect the black wire to live
• Connect the white wire to neutral
• Connect the green/yellow wire to ground
(earth)
The recommended way to install VPLs and
brackets is to install one at the time. Although it is
possible to mount the brackets first, the inherent
expansion and contraction of the aluminium
profiles, from which the VPLs are made, can cause
complications where temperatures may vary.
PLEASE NOTE! WHENEVER SINGLE AND DUAL
BRACKETS ARE USED AT THE SAME TIME RE-
MEMBER TO TAKE THE SIZE DIFFERENCE INTO
CONSIDERATION
10mm
4mm
14mm
INSTALLING THE FIXTURES
MOUNTING
Figure 19: Power cable color code
1 — Power - White
2 — Power - Yellow/Green
3 — Power - Black
4 — Data - White
5 — Data - Green
6 — Data - Red
7 — Data - Blue
8 — Data - Shield