12
Product Version 1.0 | Revision D | Released 2023-01-10
CONNECTING THE VPL SERIES
PERMANENTLY CONNECTING POWER & DATA
The VPL Series can operate on any 200–240 V, 50/60 Hz AC mains power supply. Power is connects to the fixture via
a Power+Data joiner or inserter (not included) (see figure 11 for connection diagram).
Figure 11: VPL Connection diagram
PLEASE NOTE! FOR SPECIAL INSTALLATIONS WITH MORE VPL STRINGS IN COMBINATION WITH MORE CABLE
LENGTHS IN BETWEEN, PLEASE CONTACT YOUR DISTRIBUTOR OR SGM SUPPORT.
Mains power
200-240 V
50/60 Hz
Artnet/sACN
Kling-N
et
Artnet
sACN
10 Amp Type B Circuit
breaker, 3rd party
VPL - 1220-20
VPL - 610-20
VPL - 305-20
Main Power 200-240 V 50 / 60 Hz
Max 5 m.
Multicore 8 PIN Connector 1 x Shield, 3 x Power, 4 x Signal
Max. 85m/278.8 ft (230V) or 60m/196.8ft (200V) from the breaker to the last unit
VPL Touring bracket
(For third party clamps)
VP End cap
VPL Dual installation bracket
VPL Single installation bracket
Power
Data
VP cable
VP Power + Data Joiner
VPL Power
Inserter
Installation Connection and Mounting
VPL POWER & DATA JOINER
The VP Power + Data Joiner (see figure 12) is designed to join
power and data for a daisy chain of VP fixtures. One VP Power +
Data Joiner can send power and data up to 65 VPL 1220-20 units
at 240 volts and 45 units at 208 volts. It is recommended to
install a 10amp type B circuit breaker for each string of cabled
VPL fixtures.
Power
Power + Data
RJ-45
Figure 12: VPL Power + Data Connector