240
Finish Relay Output Time (T2)
10
00 ~ 99 (Unit:0.1sec.)
241
Weight Judge Delay Time (T3)
10
00 ~ 99 (Unit:0.1sec.) –Checker Mode
243
Weight Judge Time (T4)
10
00 ~ 99 (Unit:0.1sec.) –Checker Mode
244
Error relay out delay Time (T5)
10
00 ~ 99 (Unit:0.1sec.) –Checker Mode
245
Error relay out Time (T6)
10
00 ~ 99 (Unit:0.1sec.) –Checker Mode
251
Zero state lamp output standard
00
00 : Near Zero
01 : Zero
253
Near zero output Setting Under tare ON
state
00
00:Zero Output
01:Actual zero output except Tare weight
254
Set point save
00
00:Apply to current P/N
01:Apply to every P/N
301
Parity / Stop bit
00
00:Databit 8, Stopbit 1, Paritybit Non
01:Databit 8, Stopbit 1, Paritybit Odd
02:Databit 8, Stopbit 1, Paritybit Even
03:Databit 7, Stopbit 1, Paritybit Odd
04:Databit 7, Stopbit 1, Paritybit Even
302
Serial Communication Speed
02
00: 2,400bps 01: 4,800bps 02: 9,600bps
03: 14,400bps 04: 19,200bps
05: 28,800bps 06: 38,400bps
07: 57,600bps 08: 76,800bps
09: 1115,200bps
303
Data transmission mode
00
00:Simplex / Stream Mode
01:Duplex / Command Mode
02:Print Mode
03:Modbus(RTU)
304
“Check-Sum” under command mode
00
00:Disuse, 01:Use
305
Data Format under Stream Mode
00
00:Format1, 01:Format2, 02:Format3
03:Format4, 04:Format5
306
Date transference under stream mode
00
00:Countinuously
01:Single time on every steady state
02:Single time at the first steady point
03:Single time output after weighing
finish
04:When input F key
307
Modbus Transmit Data MSB/LSB location
00
00:Standard, 01:Change