- 36 -
SI 560A DIN SIZE WEIGHING INDICATOR
6-1-5. Modbus Memory Map
-
RO : Read Only
- RW : Read Write
- Each P/N’s set point can’t over max capacity of Indicator.
ex)35.00kg = 3,500 (0xDAC)
- When you input date and time, it should be 6digit.
ex) 1
st
January 2014 = 140101 (0x22345)
15(H) : 50(M) : 17(S) = 155017 (0x25D89)
- Refer the memory register for regarding Lamp, Error, Digital Input, Standard Key,
Special Key
- Modbus Function Codes
'03' (0x03) : Read Holding Registers
'04' (0x04) : Read Input Registers
'06' (0x06) : Write Single Registers
'16' (0x10) : Write Multiple Registers
- CRC Check Method is CRC-16.
Add
-
ress
Leng-
th
Feature
Description
1
2
RO
Capacity
3
2
RO
None(0x00)
5
2
RO
Analog Value
7
2
RO
Span Value
9
1
RO
Division
10
1
RO
Decimal point
11
2
RO
Current Weight
13
2
RO
Tare Weight
15
2
RO
Measured Weight
17
2
RO
Digital input
19
2
RO
Lamp
21
2
RO
Error
23
1
RO
Weighing Mode
24
1
RO
Weighing Step
25
2
RO
Current P/N Sub-total
count
27
2
RO
Current P/N Sub-total
Weight
29
1
RO
Current P/N Under Count
30
1
RO
Current P/N Pass Count
31
1
RO
Current P/N Over Count
32
1
RO
Current P/N Error Count
33
2
RO
Grand total Count
35
2
RO
Grand total Weight
437 2
RW
Date
439 2
RW
Time
441 1
RW
Key value
443 1
RW
Relay output
444 1
RW
P/N
445 2
RW
Current P/N Set point 1
447 2
RW
Current P/N Set point 2
449 2
RW
Current P/N Set point 3
451 2
RW
Current P/N Set point 4