- 30 -
SI 560A DIN SIZE WEIGHING INDICATOR
◆Weighing mode 3 – Packer mode (Function 223 – 03)
Weight set
SP1
SP2
SP3
Set point
Drip
Free fall
Time set
Time
Contents
t1
Finish Relay Output Delay Time (Function 239)
When Function 103-3 or 103-6, save the date after t1 time.
t2
Finish Relay Output Time(Function 240)
Relay output
Relay
Condition
Relay
Condition
OUT 1
Start input (ON)
Current weight ≥ SP1 - SP3
(OFF)
OUT 2
Start input (ON)
Current weight ≥ SP1 – SP2 (OFF)
OUT 3
When current weight reaches
SP1 set value,
after t1 time, during
t2 time (ON)
OUT 4
Within near zero range (Function
201) (ON)
Near Zero
Zero
Tare Input
Start Input