3 Operation
Battery
Used to set the type of disposable/rechargeable battery used.
NOTICE! Damage possible due to device overheating
If the battery type is not correctly set, the device can overheat.
●
Always enter the correct battery type.
Autostart
Sets the application that is automatically activated when the de-
vice is switched on.
Gas type CxHy
Sets the gas type (methane CH
4
, propane C
3
H
8
, butane C
4
H
10
)
which is automatically used when the device is switched on.
Unit %LEL
Used to set the unit of measurement. Only applies to
Warning
%LEL
and
Warning ExTox
applications.
PPM multiplicator
Set the amplification factor for the lower ppm range.
Measurement x factor = displayed measurement
Application:
– Inspection above ground
Device inspection
Used to switch the integrated device inspection on or off.
Factory settings
Used to reset the device settings to the factory settings.
Language
Sets the language.