8
2 Features
2.2
Sensors
The device features three types of sensor:
● Gas-sensitive semiconductor (SC)
● Infrared sensor (IR)
● Electrochemical sensor (EC)
Application
Gas Measuring range
Sensors
Inspection above
ground
CH
4
1 ppm – 10 % vol.
SC, IR
Plants
CH
4
1 ppm – 100 % vol. SC, IR
Measuring in bar
holes
CH
4
0.0 – 100 % vol.
IR
CO
2
0 – 30 % vol.
IR
O
2
0 – 25 % vol.
EC
Ethane analysis
CH
4
---
Gas chroma-
tograph, SC
C
2
H
6
C
3
H
8
Structure
CH
4
1 ppm – 100 % vol. SC, IR
CO
0 – 500 ppm
EC
Gas measuring
CH
4
0.0 – 100 % vol.
IR
Warning %LEL and
warning ExTox
CH
4
0 – 100% LEL
IR
CO
0 – 500 ppm
EC
CO
2
0 – 5 % vol.
IR
O
2
0 – 25 % vol.
EC
H
2
S 0 – 100 ppm
EC