![SEW Movitrac B Operation Instructions Manual Download Page 78](http://html1.mh-extra.com/html/sew/movitrac-b/movitrac-b_operation-instructions-manual_1250009078.webp)
78
Operating Instructions – MOVITRAC® B
5
Starting the motor in manual mode
Startup
5.6
Starting the motor in manual mode
You have to exit manual mode before you can enable the motor via terminals.
5.6.1
Analog setpoint specification
The following table shows which signals must be present on terminals X11:2 (AI1) and
X12:1 – X12:4 (DIØØ – DIØ3) when the "unipolar/fixed setpoint" setpoint is selected
(
P100
) in order to operate the drive with an analog setpoint entry. This terminal assign-
ment is an example. It can be changed via parameters
P601 – 608
. CW/stop DIO1 is
permanently assigned.
Function
X11:2 (AI11)
Analog
input n1
X12:1
(DIØØ)
/Control-
ler inhibit
1)
X12:2 (DIØ1)
CW/stop
2)
X12:3
(DIØ2)
CCW/stop
X12:4
(DIØ3)
Enable/sto
p
X12:5
(DIØ4)
n11/n21
X12:6
(DIØ5)
n12/n22
Controller inhibit
X
0
X
X
X
0
0
Stop
X
1
X
X
0
0
0
Enable and stop
X
1
0
0
1
0
0
Clockwise at
50% n
max
5 V
1
1
0
1
0
0
Clockwise at n
max
10 V
1
1
0
1
0
0
Counterclockwise
at 50% n
max
5 V
1
0
1
1
0
0
Counterclockwise
at n
max
10 V
1
0
1
1
0
0
1) No default setting
2) Fixed assignment
0 = 0 signal
1 = 1 signal
X = Not relevant
00
I
Summary of Contents for Movitrac B
Page 2: ...SEW EURODRIVE Driving the world...
Page 259: ......