Operating Instructions – MOVITRAC® B
8
Technical data for braking resistors, chokes and filters
Technical data
8.3.6
HF... output filter
HF output filters are sine filters for smoothing the output voltage of inverters. HF... output
filters (apart from HF450-503 and HF180-403) are approved according UL/cUL in con-
junction with MOVITRAC
®
.
HF... output filters are used in the following cases:
• In group drives (several motor leads in parallel); the discharge currents in the motor
cables are suppressed.
• To protect the motor winding insulation of non-SEW motors which are not suitable for
inverters
• For protection against overvoltage spikes in long motor cables (> 100 m).
Observe the following notes:
INFORMATION
• Output filters can only be operated in V/f and VFC operating modes.
• Do not use output filters in hoist applications.
• During project planning of the drive, take the voltage drop in the output filter into ac-
count and the reduced motor torque that results. This applies particularly to AC
230 V units with output filters.
Output filter type
HF008-503
1)
HF015-503
1)
HF022-503
1)
HF030-503
1)
HF040-503
1)
HF055-503
1)
Part number
826 029 X
826 030 3
826 031 1
826 032 X
826 311 6
826 312 4
Nominal voltage V
N
3 × AC 230 – 500 V, 50/60 Hz
2)
Earth-leakage current at U
N
∆
I
0 mA
Power loss at I
N
P
V
25 W
35 W
55
65 W
90 W
115 W
Interference emission via
unshielded motor cable
According to limit value class C1/C2 in accordance with EN 61800-3
3)
Ambient temperature
ϑ
amb
0 °C to +45 °C (reduction: 3% I
N
per K to max. 60 °C)
Degree of protection (EN 60529)
IP20
Connections /
Tightening torque
M4 terminal studs
1.6 Nm ±20 %
Mass
3.1 kg (6.8 lb)
4.4 kg (9.7 lbs)
10.8 kg (23.8 lb)
Assignment of AC 400/500 V units
Voltage drop at I
N
∆
U
< 6.5% (7.5 %) at AC 400 V / < 4% (5%) at AC 500 V at f
Amax
= 50 Hz (60 Hz)
Nominal through current I
N 400 V
(at V
line
= 3 × AC 400 V)
Nominal through current I
N 500 V
(at V
line
= 3 × AC 500 V)
AC 2.5 A
AC 2 A
AC 4 A
AC 3 A
AC 6 A
AC 5 A
AC 8 A
AC 6 A
AC 10 A
AC 8 A
AC 12 A
AC 10 A
Nominal operation (100%)
3)
0005 – 0011
0014 / 0015
0022
0030
0040
0055
Increased power (125%)
3)
0005
0008 / 0011
0014 / 0015
0022
0030
0040
Assignment to AC 230 V units
Voltage drop at I
N
∆
U
–
< 18.5% (19%) at AC 230 V with f
Amax
= 50 Hz (60 Hz)
Nominal through current I
N 230 V
(at V
line
= 3 × AC 230 V)
AC 4.3 A
AC 6.5 A
AC 10.8 A
AC 13 A
AC 17.3 A
AC 22 A
Nominal operation (100%)
3)
–
–
0015/0022
–
0037
0055
Increased power (125%)
3)
–
–
0015/0022
–
–
0037
1) Approved to UL/cUL in conjunction with MOVITRAC
®
inverters. SEW-EURODRIVE provides proof of approval on request.
2) A reduction of 6% I
N
per 10 Hz applies above f
A
= 60 Hz for the nominal through current I
N
.
3) Observe the chapter on EMC-compliant installation according to EN 61800-3 in the SEW documentation