18
MOVIDRIVE
®
MD_60A, Absolute Positioning
INTERBUS
(DFI11A)
Technical data
Pin assignment
Option
INTERBUS fieldbus interface type DFI11A
Part number
822 723 3
Startup and diagnostic tool
MOVITOOLS software and DBG11A keypad
Connection
Remote bus input: 9-pin sub D plug
Remote bus output: 9-pin sub D socket
RS-485 transmission technology, 6-core shielded and
twisted-pair cable
Module ID
E3
hex
= 227
dec
Weight
0.2 kg (0.44 lb)
1.
DIP switch for setting the number of process data items
2.
4
×
green LED: Diagnostic LEDs
3.
1
×
red LED: Diagnostic LED
4.
9-pin sub D plug: Remote bus input
5.
9-pin sub D socket: Remote bus output
DFI
INTERBUS-S
Module Ident.
227
1.
2.
3.
4.
5.
04435AXX
Fig. 11: Assignment of the 9-pin sub D socket of the incoming remote bus cable and the
9-pin sub D plug of the outgoing remote bus cable
(1) 9-pin sub D socket of the incoming remote bus cable
(2) Twist the signal wires together!
(3) Conductive connection is necessary between the plug housing and the shield!
(4) 9-pin sub D plug of the outgoing remote bus cable
(5) Jumper pin 5 with pin 9!
6
1
7
2
3
/DO
DO
/DI
DI
COM
E
Q
Q
(1)
(2)
(3)
6
1
7
2
3
5
9
/DO
DO
/DI
DI
COM
(4)
(2)
(3)
(5)
GN
YE
PK
GY
BN
GN
YE
PK
GY
BN
Summary of Contents for movidrive md_60a
Page 1: ...MOVIDRIVE MD_60A Absolute Positioning Edition 03 2001 Manual 1051 0117 EN...
Page 2: ...SEW EURODRIVE...
Page 4: ...4 MOVIDRIVE MD_60A Absolute Positioning Documentation Safety and warning instructions...
Page 5: ...MOVIDRIVE MD_60A Absolute Positioning 5 2 1 Application fields 18...
Page 27: ...MOVIDRIVE MD_60A Absolute Positioning 27 Scaling 04442AEN Fig 18 Setting the scaling 0 0 I...
Page 33: ...MOVIDRIVE MD_60A Absolute Positioning 33 Jog mode Note 04448AEN Fig 24 Jog mode 0 0 I...
Page 37: ...MOVIDRIVE MD_60A Absolute Positioning 37 Moving clear of limit switches...
Page 39: ...MOVIDRIVE MD_60A Absolute Positioning 39 6 3 Error messages Display List of faults 01038AXX...
Page 42: ...10 2000...
Page 43: ...10 2000...